Adjusting MDS Sensor
1.
Loosen both upper Phillips
head screws through the
access in the Bill Dispenser
frame (Only
slightly loosen
the screws)
2.
Turn slotted screw very
slowly until a reading close
to E7 is shown on diagnostic
display (+ 4 tolerance)
3.
Tighten Phillips head screw
(1)Loosen
the top
Phillips
head
screw on
both
sides
slightly
(2)Turn
Slotted screw
on right side
very slowly
until a
reading close
to E7 is
shown on
diagnostic
display
Adjustments to the MDS sensor should only be made by an ICS
Technician unless authorized by ICS Support
Level 2
Left side view
Loosen the top
Phillips head
screw only
(1)
MDS sensor
bracket
Summary of Contents for Auto Sentry-eXP
Page 1: ...Auto Sentry eXP Maintenance Revised 12 21 07...
Page 32: ...Sensor Location TOP FRONT...
Page 46: ...PS1 Sensor PSI Sensor Prism location Viewed from back of Bill Dispenser...
Page 52: ...PS1 Sensor Cleaning Remove two screws from Close tab bracket Push up on Open tab to release...
Page 63: ...Pick Assembly Cleaning Level 2...
Page 66: ...Opening the Close Tab Area Remove the two screws on the Close Tab and fold down Level 2...
Page 67: ...Clean the entire area Blow off the Dust Clean all rollers Metal Rubber Level 2...
Page 78: ...Reinstall the Pick Assembly Level 2...
Page 86: ...Proper Drive Belt Configuration shown with cover removed Level 2...
Page 87: ...Credit Card Reader Maintenance Removing Foreign Objects Credit Card Reader Cleaning Procedure...
Page 90: ...Credit Card Reader Foreign Object Removal...
Page 99: ...Bill Acceptor Maintenance Bill Acceptor Maintenance Bill Acceptor Cleaning Procedure...
Page 100: ...Bill Acceptor Status LED...
Page 101: ...Bill Acceptor Status LED...
Page 102: ...Bill Acceptor Status LED...
Page 103: ...Bill Acceptor Status LED...
Page 104: ...Bill Acceptor Status LED...
Page 105: ...Bill Acceptor Connector Pin outs Cartridge Side...