Tunnel Master® wbc Installation Guide
Page 36
Tunnel Master® wbc Installation Guide
Page 36
Exterior of Tunnel Master® wbc
Figure 28. Exterior Panel
Ultrasonic Truck Bed Sensor
ID
Description
1
The display is a 640 × 480 color
monitor.
2
On-board Keyboard.
The ultrasonic sensor can detect the bed of a pickup truck.
NOTE:
This feature is optional and additional fees apply.
Figure 29. Ultrasonic Truck Bed Sensor Mounted
Specification
Description
Specification
Description
Range
1–9 feet
IP Code
IP65
Housing
ABS or PVC
Sensor Adjust
RS-485 interface
Outputs
RS-485 and NPN
Operating temp.
–13° F to 158° F (-25° C to 70° C)
Supply Voltage
24 V DC
Resolution
Evaluation range [mm]/4000, but
≥ 0.35 mm
Power Consumption
≤ 900 mW
Repeat Accuracy
≤ 0.1% of full-scale value
Transducer Type
Ceramic
Temp. Comp.
≤ 2% from full-scale value (with
temperature compensation)
Ratings
NEMA 4x
Common Mode
Operation
≤ 13 Hz
Beam Pattern
24 degrees off axis (when
operating with high sensitivity)
Cable
Cable is hard wired to sensor
and cut to 18” to fit into NEMA
enclosure on terminal blocks.
Table 12. Exterior Descriptions of the Tunnel Master® wbc
Table 13. Ultrasonic Sensor Specifications