70
«
Deck Open Problem
»
Code: E19
LED Light Display: 5 red +1 red
LCM Display: As shown in figure below
Cause:
1. The deck is open for over 30 seconds.
2. The reject bar has problem.
Corrective Measure:
1. Close the deck and reactive the power.
2. Retry once a minute for 10 times, if the problem is not
resolved then remove the LCM panel to leave this
exception and notify ICT personnel for support.
«
Motor Error
:
A&B
»
Code: E20
LED Light Display: 7 red
LCM Display: As shown in figure below
Cause: Both the first and second group motors cannot be positioned.
Corrective Measure: Please see reference instructions for “E21” and “E22” below.
Flight Deck
Error E19
Coin Jam
E20