OUTPUT SETUP
This page allows you to configure the output settings of the panel. In the
Select an Output
to edit box,
click on the output number of the output you wish to configure. To save any changes to the output
settings, click on
Save Settings
at the bottom of this page.
To copy the configuration settings from one output to all of the other outputs, click on
Copy Settings to
All
, and then click on
Save Settings
to save the new settings.
OUTPUT SETTINGS
Label:
Allows you to assign a custom name to each individual output. The output names are displayed
on the
Status & Control
page, as well as on the LCD screen.
Output State after Panel Reset:
Allows you set the output state of the selected output after a power
failure or a soft reset. Select one of the following options:
- “Restore Last State”: If this option is selected, the panel will remember if this output was enabled or
disabled prior to the power failure or reset. The output will restored to the same state after the panel
starts up.
- “Enable Output”: If this option is selected, this output will always be enabled after the panel starts
up after a power failure or reset.
- “Disable Output”: If this option is selected, this output will always be disabled after the panel starts
up after a power failure or reset.
Ignore Fuse Status:
If this box is checked, the panel will not monitor the status of the fuse for the
selected output. This will prevent nuisance alarms if an unused output does not have a fuse in place.
Enable Power Cycling:
Checking this box will turn on power-cycling for the selected output. When
Power-Cycling is enabled for an output, the output will automatically be re-enabled after a selectable
period of time after it is disabled from the
Status & Control
page. Power-Cycling is useful for remotely
resetting power to hardware that is needed for network connectivity to the panel.
If Power Cycling is enabled for any outputs, the
Sequence/Cycle Delay
setting must be also set on the
Device Setup
page.
If multiple outputs with Power-Cycling enabled are disabled from the
Status & Control
page at the
same time, they will be re-enabled in sequence.