ELECTRIC BICYCLE METER KT
—
LCD7C Product User Manual
- 22 -
6Km/h, after power assist, handlebar is full speed.
Stop power assist,
return the handlebar speed limit
is 6Km/h.
4
Handlebar gears is distinguished
according to the display meter.
Non-zero startup handlebar, Handlebar gears is
distinguished according to the display meter.
5
Retain
Retain
When C4 = 2 is confirmed, "specified speed limit value of handlebar" flashes,
press
(UP) button or
(DOWN) button for short to make selection, and the
default value is 20.
When C4 = 4 is confirmed, the "percentage value of the first gear speed accounts
for its full speed" of the power assist gear flashes, press
(UP) button or
(DOWN) button for short to make selection, and the default value is 50%. The
percentage values of other gears divide automatically in equal.
After finishing C4 parameter setting, press
button (SW) to save the current set
values and enter C5 parameter setting interface.
○
C5
Controller Maximum Current Adjustment Setting
Enter C5 parameter setting interface, C5 parameter column flashes.
C5 parameter setting interface
C5 is controller maximum operating current adjustment setting(tiny-adjustment of
limit current value), the default value is 10, setting range is 0-10,press
button (
UP
)
or
button
(DOWN)
for selection.
C5 parameter definition table
:
C5 value
Maximum current value(A)