Trouble Inputs
Each keypad can monitor up to 8 trouble inputs.
Trouble inputs are used to monitor the module status and in most cases are not physically connected to an
external input.
The following table details the trouble inputs that are configured in the system and the trouble type and group
that they activate.
Trouble
Input
Function
Type
Group
KPXXX:01
Module Tamper
Opens when the keypad is removed from the wall.
Module
Tamper
System
KPXXX:02
Reserved
-
-
KPXXX:03
Keypad Panic
Keys 1 and 3 are pressed together generating a panic message.
-
-
KPXXX:04
Keypad Duress
A user code with the duress option enabled has entered a code on the
keypad.
-
-
KPXXX:05
Reserved
-
-
KPXXX:06
Reserved
-
-
KPXXX:07
Too Many Codes
Too many incorrect codes have been entered at the keypad and it has
been locked out for the programmed lockout time.
Number of
Attempts
Access
KPXXX:08
Module Offline
The keypad has either been removed from the system or lost
communications.
Module Lost System
Replace 'xxx' with the appropriate address of the module that you are programming.
The panic and duress features have not been evaluated for UL/ULC installations.
PRT-TS50 | LCD Touchscreen Keypad | Installation Manual
12