3
ENGLISH
EN
The charging station (indside)
10
Screws wall mouting
11
SIM Card Slot
12
UTP (Ethernet) Connection
13
Connection LEDs and display
14
Isolator switch
2.2 LED-status display
The ICU Eve comes with separate LEDs on each side which indicate the status of each socket. Please find
below an overview of the different states:
Status LED
Meaning
15
•
Available
16
•
Cable is connected in the charging station and waiting
•
Identification with RFID is done and now waiting for cable to be connected
17
•
The charging station and vehicle are communicating
•
Electric vehicle is full or charging is on hold
18
•
Vehicle is charging
19
•
External error
•
The cable has been left too long in the charging station without starting a charging
process
20
•
The charging station has an internal error
21
•
The card reader is active
22
•
The used card is not authorized
Product
Identification Label
The identification label (
8
) specifies, for example,
the model, production date and serial number. It can
be found on the bottom side of the charging station.
Always make reference to the serial number when
contacting to Alfen ICU so that you receive the fas
-
test support.