Before attempting to service machinery, the machine must be turned
off and the power and air locked out.
Start by removing the back cover from the applicator using a 3mm hex wrench. Next,
install the three yellow relays in the sockets marked K2, K3, and K4 on the main circuit
board. Looking down on the top of the relay with the text showing, the black line on the
relay must be to the inside of the board. Carefully install the black solid-state relay in the
socket marked K1 on the main circuit board. Locate and remove the round hole plug on
the back of the electronics module. From the outside of the electronics module, push the
rectangular twelve conductor connector through the hole. Install the internal wiring
harness with the four fasteners supplied in the kit. Plug the twelve conductor connector in
the socket on the board marked J15. Replace the back cover and reconnect any cables
disconnected during removal. Return power to the printer/applicator and set the outputs
per the user manual. See the Drawings and Diagrams section for the user connection pin-
out for the system status output kit.
Summary of Contents for 252
Page 1: ...Model 252 Label Printer Applicator Operator Technical Manual...
Page 10: ...I GENERAL...
Page 19: ...II OPERATING FUNDAMENTALS...
Page 25: ...III INITIAL SETUP...
Page 28: ...Model 252 Label Printer Applicator Operators Technical Manual 3 1 12 Declaration of Conformity...
Page 116: ...Model 252 Label Printer Applicator Operators Technical Manual 0 V DRAWINGS AND DIAGRAMS...
Page 160: ...VI COMPONENT INFORMATION...
Page 161: ...Model 252 Label Printer Applicator Operators Technical Manual 1 MiniBeam Photocell...
Page 162: ...Model 252 Label Printer Applicator Operators Technical Manual 2...
Page 163: ...Model 252 Label Printer Applicator Operators Technical Manual 3...
Page 164: ...Model 252 Label Printer Applicator Operators Technical Manual 4...