5.14.2 Setting the Pressures
The main system pressure is set at the filter regulator assembly. Pull up on the adjusting
knob to unlock it, and then rotate the knob to set the pressure. The setting is displayed on
a gauge on the side of the assembly. The main pressure should be set around 80 to 90
psi.
The pressure settings for the tamp cylinder, air assist and vacuum are individually
adjustable and can be fine tuned for the application. To adjust the pressures, remove the
two M4 screws that secure the back cover using a 3mm hex wrench. Remove the back
cover.
Using a small adjustable wrench, loosen the locking nut on the regulator to be adjusted.
Adjust the pressure setting by inserting a flat blade screwdriver into the adjusting screw.
To increase the pressure setting, turn counterclockwise, to decrease turn clockwise.
VACUUM
REGULATOR
TAMP
REGULATOR
AIR ASSIST
REGULATOR
LOCKING
NUT
ADJUSTING
SCREW
Summary of Contents for 252
Page 1: ...Model 252 Label Printer Applicator Operator Technical Manual...
Page 10: ...I GENERAL...
Page 19: ...II OPERATING FUNDAMENTALS...
Page 25: ...III INITIAL SETUP...
Page 28: ...Model 252 Label Printer Applicator Operators Technical Manual 3 1 12 Declaration of Conformity...
Page 116: ...Model 252 Label Printer Applicator Operators Technical Manual 0 V DRAWINGS AND DIAGRAMS...
Page 160: ...VI COMPONENT INFORMATION...
Page 161: ...Model 252 Label Printer Applicator Operators Technical Manual 1 MiniBeam Photocell...
Page 162: ...Model 252 Label Printer Applicator Operators Technical Manual 2...
Page 163: ...Model 252 Label Printer Applicator Operators Technical Manual 3...
Page 164: ...Model 252 Label Printer Applicator Operators Technical Manual 4...