Thermal Imaging Integrated Network Camera
User Manual
3 Installation
Issue V1.0 (2014-01-10)
7
3.2 Installation Mode
The thermal imaging integrated camera can be installed on the ceiling or the wall. You
can select the appropriate installation according to your requirements. If the camera
needs to be installed on the cement wall, you need to install the expansion screws (the
mounting holes of the screws must be consistent with that of the support), and then
install the support.
NOTE
The wall where the support is mounted must be able to withstand at least three times of the
total weight of the support and the camera.
3.3 Installation Procedure
Step 1
Remove the installation location labels delivered with the camera. Stick the installation
location labels on the ceiling or the wall, as shown in Figure 3-1.
NOTE
If the installation uses the back leading mode, pouch a leading-out hole on the ceiling or
the wall, as shown in the area highlighted in red in Figure 3-1. (This manual uses the
back leading mode as an example.)
If the installation uses the side leading mode, lead the multi-connector combination cable
from the side notch on the bottom of the camera.
Figure 3-1
Installation location label
Location label
Wall
Step 2
According to the location hole positions shown in the installation location label, punch
four location holes with diameter 5 mm on the ceiling or the wall.