Touchscreen Terminal.  Rev 1.03  November 2009

Installation Manual.

Installing the Touchscreen Terminal

-

Choose an appropriate mounting location where the Touchscreen Terminal can
be installed on a flat, solid, vertical surface.

-

Ensure that the LCD display will be at eye level for an adult of average height.
e.g. Eye level for an average adult is approximately 165cm (65 inches).

-

Install appropriate LAN cabling from this location to a suitable point on the
existing LAN.  Note the following points:
1.  Installation of a Touchscreen Terminal may also require installation of a
separate battery-backed power supply.

See Note 1 below and “LAN wiring” on page 6.

2.  Power should not be connected to this LAN cable until installation of the
Touchscreen Terminal is complete.

-

Install the rear casing on the wall using 2 to 6 countersunk screws or bolts in
the holes provided.  Remember to insert the LAN cable through the cable entry
cutout first.  

Refer to Installation template supplied on the back page.

-

Connect the LAN wiring into the Screw Terminal block T1, and fit or remove the
Termination link, J10, as required.

Refer to “Connections & Link options” and “LAN wiring” on pages 4 to 6 for
details.

-

Position the two tabs at the top of the front casing into the retaining slots at the
top of the rear casing, then lower the front casing onto the rear casing until it
clicks into place.

IMPORTANT NOTES.

1. CAUTION.  The Touchscreen Terminal draws between 200 and 300mA.

(This is approximately 6 times that of an LCD Terminal)  Ensure that an
adequate power supply source is available.

2. CAUTION.  Take care not to damage PCB tracks or components during

installation.

7

2

Touchscreen Terminal Parts List

-

Touchscreen Terminal assembly with protective film on LCD display.

-

Installation manual and mounting template.  (This document)

-

Accessory kit containing:
-

2 x 2 way miniature screw terminal blocks.

-

1 x Jumper link.

Specifications

Power Supply Input:

11V to 14V DC

Operational Current:

Idle:   200mA

Max:  300mA

Physical dimensions:

Height:  158mm.

Width:  107mm.

Depth:  18mm.

Installation environment:

0º - 40º C @15% to 85% Relative humidity.
(non-condensing)

Screen:

3.5 inch color.

Default Layouts:

1. Control: 6 Home Auxiliaries.  HA001 to 006.

Security: 4 Areas.  Area 001 to 004.

2. Control: 6 Home Auxiliaries.  HA001 to 006.

Security: 4 Areas.  Area 001 to 004, + 2 Home Auxiliaries.  HA007 & 008.

3. Control: 16 Home Auxiliaries over 3 screens.  (4 + 6 + 6) HA001 to 016.

Security: 4 Areas.  Area 001 to 004, + 2 Area Lists.

Beeper & Backlight activation:

Kxx:X04

Pulsing beeper.

Kxx:X05

Continuous beeper.

Kxx:X06

Backlight on.

Inner Range Website:

www.innerrange.com

Summary of Contents for Concept 4000

Page 1: ...or each Touchscreen used in the system e g The Areas and Diary messages to be displayed operations allowed and which of those operations require the user to log in with a PIN code This allows each Touchscreen to provide access to relevant functionality Three default display layouts are currently available each with 2 or more screens in addition to the main menu screen See page 7 for details Insigh...

Page 2: ...on the two tabs at the top of the front casing into the retaining slots at the top of the rear casing then lower the front casing onto the rear casing until it clicks into place IMPORTANT NOTES 1 CAUTION The Touchscreen Terminal draws between 200 and 300mA This is approximately 6 times that of an LCD Terminal Ensure that an adequate power supply source is available 2 CAUTION Take care not to damag...

Page 3: ...i d n o C n o i t a n a l p x E y d e m e R s w o h s y a l p s i D s s e r d d a e l u d o M h g i h o o t y r o m e m r o n o i s r e v e r a w m r i f A s e o d t a h t d e s u g n i e b s i n o i t a r u g i f n o c s l a n i m r e T n e e r c s h c u o T t r o p p u s t o n R O e b t s u m e r a w m r i f e l u d o M l o r t n o C a t e B 8 5 V r O r e t a l r o 0 6 V r o f s e l b a t n o i ...

Page 4: ...mming is found in the Programming Menu by selecting 7 Installer 2 Modules then 2 Touch Term Initialization When installation and programming is complete perform the LAN Secure operation MENU 7 8 1 to enable the encryption key for the new module s and ensure that all the relevant settings are downloaded to the Touchscreen Terminal Connections Link Options 1 J1 J2 Factory use only 2 T1 LAN Connectio...