background image

SPECIFICATIONS

PINTS PER DA

Y

W

A

TTS

220
200
180
160
140
120
100

80
60

1600
1500
1400
1300
1200
1100
1000

900
800

All temperatures shown represent ambient room temperature.

Dehumidifying Capacity

Power Consumption

90˚F

90% RH

86˚F

80% RH

80˚F

80% RH

80˚F

60% RH

90˚F

90% RH

86˚F

80% RH

80˚F

80% RH

80˚F

60% RH

Summary of Contents for 700899

Page 1: ...TM Owner s Manual CG2 Commercial Grade Dehumidifier Model 700899 PLEASE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...FORE USING THE PRODUCT Unpacking the dehumidifier Please DO NOT dispose of any packaging until you have checked that the appliance is operational After removing packaging ensure the contents are intact and complete In the unlikely event of missing parts contact Ideal Air Support directly at 877 9 IDEAL 1 or support Ideal Air com DO NOT leave children unattended with any of the packaging since it i...

Page 3: ...source when not in use or before cleaning 6 Do not place objects on the product or allow objects to obstruct the inlet or outlet openings or operate in close proximity to walls or curtains etc 7 The use of attachments or accessories not recommended or sold by Ideal Air may cause injury to persons or damage to property 8 Do not attempt to dismantle the appliance 9 Do not operate the appliance on a ...

Page 4: ... Intake Grill 8 Power Cord 4 Handle 9 Drain Hose 5 Air Outlet 1 2 3 4 5 6 7 8 9 Place dehumidifier in the upright position When transporting the dehumidifier allow it rest still for 30 minutes before switching ON This is necessary to allow the refrigerant system to stabilize and avoid system damage ...

Page 5: ...ce the unattached end into a drain or run to the outdoors Ensure that water piped to the outdoors does not create a slipping hazard To avoid damaging or overworking the pump do not exceed a 10 foot vertical lift height between the pump and drain PROPER AIRFLOW IS ESSENTIAL Do not place this dehumidifier in a position where the front Air Intake Grill or rear Air Outlet is blocked by walls furniture...

Page 6: ...he same time FUNCTION Displays menu of unit functions To cycle through menu functions you must press BOTH up and down Adjustment Keys at the same time ENTER Selects and activates a function or setting PURGE Empties the water reservoir POWER ON OFF Turns the unit ON and OFF OPERATION Digital Control Panel Sta 1 P This outl 2 T 3 S Pres Pres Pres Pres Rep Yo If O W NOT the t Pres Mak ...

Page 7: ...lock Humidity Setting Timer Clock Language ID USB SD CARD GSM Clock 00 00 Y0000 M00 D00 Repeat to access year month and day Your unit may not contain these functions which are OPTIONAL If not an error message will be displayed when access is attempted OPTIONAL FUNCTIONS When the key is pressed you will see While navigating through some functions it may also display NOTE This unit has an internal b...

Page 8: ...t When set the screen will display completed and the unit will automatically resume operation 2 This unit has battery backed up memory to allow for auto restart If the power is interrupted to the unit it will return to its previous humidity setting and continue to operation once AC power is restored NOTE Pressing the Power ON OFF key during timer operation will not cancel timer settings Also the u...

Page 9: ...sconnecting the power cord from the outlet OPERATION Press the Power ON OFF key once to turn the power OFF The LCD screen will display the following message Dehumidifier off Draining The water pump will turn on automatically and run for 40 seconds to drain the residual condensate water in the dehumidifier To avoid water spillage DO NOT move the dehumidifier for at least three minutes after turning...

Page 10: ...he filter into the dehumidifier Replacing the battery 1 Remove the screws in the four corners of the control panel 2 Once the screws are removed carefully lift the control panel to access the the Primary Control Board PCB 3 On the PCB is a CR2032 battery Remove the battery and replace with a new one 4 Refit the control panel onto the PCB 5 Refit the four screws Storing the unit Prior to storing th...

Page 11: ...t dry 1 Not enough time to dehumidify air 2 Poor air movement in room 3 Excessive moist air infiltration in room 1 Allow more time for drying 2 Increase air movement with fans 3 Reduce outside air infiltration into the room Unit collects too little water 1 Room air is too dry 2 Room temperature is too low 1 Check humidity with hygrometer 2 Increase room temperature 3 Check filter and coils clean a...

Page 12: ...ompressor has stopped operating 3 Sensor error 4 Refrigerant loss Water is not draining from the pump reservoir or there is a lack of power to the water pump Remedy 1 Check to ensure the coil sensor s terminal is securely plugged in 2 Replace the coil sensor 3 Replace display panel PCB 1 Check to ensure the humidity sensor s terminal is securely plugged in 2 Replace the humidity sensor 3 Replace d...

Page 13: ...uct in the trash on the landscape or into any unsorted waste stream It may contain hazardous substances that can leach into groundwater and find their way into the food chain This unit contains VALUABLE RESOURCES that are easy to recycle for re use Services available may include PLEASE BE RESPONSIBLE A Municipal Collection Systems Most cities and towns have established programs where electronic wa...

Page 14: ...60 140 120 100 80 60 1600 1500 1400 1300 1200 1100 1000 900 800 All temperatures shown represent ambient room temperature Dehumidifying Capacity Power Consumption 90 F 90 RH 86 F 80 RH 80 F 80 RH 80 F 60 RH 90 F 90 RH 86 F 80 RH 80 F 80 RH 80 F 60 RH ...

Page 15: ... Supply Inc may choose to provide a refurbished part or replacement system pay up to 300 to a qualified professional repair technician to perform a repair request the system be returned to Sunlight Supply for repair by IdealAirTechnicians c Replacement parts may be sent to the store location where you purchased the IdealAir product You may be asked to bring the failed part to the store to make an ...

Page 16: ...al Air for details updates and other information Contact Ideal Air Support directly at support ideal air com or call 1 877 9 IDEAL 1 Ideal Air CG2 Commerical Grade Dehumidifier Model 700899 Product defect Not working properly DO NOT return this product to the store where you purchased it For answers to the most common questions and a complete technical support library please visit www ideal air co...

Reviews: