SIX
:
ERROR CODES
This machine can identify some malfunctions itself. The error codes that may be displayed
are in the table below.
CODE
PROBLEM
E3
Humidity sensor has failed
E4
Water tank is full
E5
Temperature sensor has failed
SEVEN
:
TECHNOLOGY SPECIFICATION
TESTING CONDITIONS: 86°F & 80%RH
MODEL
DS190
POWER
115V/60Hz
86°F & 80% RH
190 pint per day
NOMINAL RATED POWER
CURRENT
10.5 AMPS
NET WEIGHT
152 lbs
SIZE
26” X 22” X 42”
4