—WATER CONNECTION—
Place the unit on a level surface, such as a benchtop or floor. In an
environment with little to no ventilation, place the unit in a central
location. In a ventilated area, place unit near the intake end. When
the unit is in the desired location, connect a water supply to the
female 6 mm / 1/4 inch inlet.
See options as follows:
• Plumb directly to a water supply (6 mm / 1/4 inch plastic
tubing is preferred).
• Connect to a garden hose fitting.
• Plumb to a storage tank higher than the fogging unit (gravity feed).
—Power Connection—
Plug the unit directly into an electrical outlet for evaluation. Listen for
a smooth, quiet operation. Motor shaft should be centered and
vertical. Make any necessary adjustments. If the power cord is
damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
—Operation—
WARNING: Designed for atomizing water only! Don’t use flammable,
toxic or corrosive liquids.
• Operating the unit using the fogging head will provide directional
fogging output and a drier fog.
• For maximum fogging and circulation, operate unit without
fogging head. Fog will propel 4 ~ 5 feet above the unit.
—TROUBLESHOOTING—
No Fog:
Check for motor rotation. If motor is operating properly, there will be
an adequate amount of water in the pan (1/4” to 1-1/4”).
If the pan runs dry, the float valve may be sticking in the up posi-
tion. If so, the inlet water pressure needs to be reduced. If water
supply is adequate, check the tapered pump for internal calcium
build-up. Remove, inspect and clean as needed.
Overflowing Pan:
An overfilled pan can cause poor quality fog and wetness around
the unit.
A leaky float valve or a float that has filled with water may be the
problem. To check the float, raise it out of the water and visually
inspect it. No water should be inside and it should not sink.
If OK, then check for leaky valve. Turn water off and remove the
fogger from the pan.
Empty the pan and towel dry. Hold the float in the up position and
turn on the water.
If any water enters the pan while the float is in the up position, the
float valve needs to be replaced.
IDEAL-AIR™
IDEAL-AIR™
PRODUCT# 700860
PRODUCT# 700860