background image

—WATER CONNECTION—

 
Place the unit on a level surface, such as a benchtop or floor. In an 
environment with little to no ventilation, place the unit in a central
location. In a ventilated area, place unit near the intake end. When 
the unit is in the desired location, connect a water supply to the 
female 6 mm / 1/4 inch inlet. 

See options as follows:
• Plumb directly to a water supply (6 mm / 1/4 inch plastic
tubing is preferred).

• Connect to a garden hose fitting.

• Plumb to a storage tank higher than the fogging unit (gravity feed).

—Power Connection—

Plug the unit directly into an electrical outlet for evaluation. Listen for 
a smooth, quiet operation. Motor shaft should be centered and
vertical. Make any necessary adjustments. If the power cord is
 damaged, it must be replaced by the manufacturer, its service agent 
or similarly qualified persons in order to avoid a hazard.

—Operation—

WARNING: Designed for atomizing water only! Don’t use flammable, 
toxic or corrosive liquids.

• Operating the unit using the fogging head will provide directional 
fogging output and a drier fog.   

• For maximum fogging and circulation, operate unit without
fogging head. Fog will propel 4 ~ 5 feet above the unit.  

—TROUBLESHOOTING—

No Fog: 

Check for motor rotation. If motor is operating properly, there will be 
an adequate amount of water in the pan (1/4” to 1-1/4”). 

If the pan runs dry, the float valve may be sticking in the up posi-
tion. If so, the inlet water pressure needs to be reduced. If water 
supply is adequate, check the tapered pump for internal calcium 
build-up. Remove, inspect and clean as needed.

Overflowing Pan:

An overfilled pan can cause poor quality fog and wetness around 
the unit. 

A leaky float valve or a float that has filled with water may be the 
problem. To check the float, raise it out of the water and visually 
inspect it. No water should be inside and it should not sink. 

If OK, then check for leaky valve. Turn water off and remove the 
fogger from the pan. 

Empty the pan and towel dry. Hold the float in the up position and 
turn on the water. 

If any water enters the pan while the float is in the up position, the 
float valve needs to be replaced.

IDEAL-AIR™ 

IDEAL-AIR™ 

PRODUCT# 700860

PRODUCT# 700860

Summary of Contents for GSH75

Page 1: ...COMMERCIAL GRADE GSH75 HUMIDIFIER 75 PINTS PER DAY PRODUCT 700860 ...

Page 2: ...COMMERCIAL GRADE GSH75 HUMIDIFIER EXPLODED VIEW DIAGRAM IDEAL AIR PRODUCT 700860 27 20 29 40 33 34 39 38 37 36 26 32 19 25 23 22 21 17 15 18 16 31 24 30 35 ...

Page 3: ...ot let children play with the appliance If the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard Unplug the appliance during filling and cleaning Follow the instructions included regarding filling cleaning and descaling Maximum permissible water pressure in pascals 1 2 MPa Minimum permissible water pressure in p...

Page 4: ...ging unit gravity feed Power Connection Plug the unit directly into an electrical outlet for evaluation Listen for a smooth quiet operation Motor shaft should be centered and vertical Make any necessary adjustments If the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Operation WARNING Designed for atomizing...

Page 5: ...ded Overflowing Pan An overfilled pan can cause poor quality fog and wetness around the unit A leaky float valve or a float that has filled with water may be the problem To check the float raise it out of the water and visually inspect it No water should be inside and it should not sink If OK then check for leaky valve Turn water off and remove the fogger from the pan Empty the pan and towel dry H...

Page 6: ...calcium build up If build up deposits are present disconnect the water and take the unit outside Pour calcium dissolving solvent available in local hard ware stores in pan and operate unit outside to soften and remove the deposits About once a year remove the housing to check the SST Atom izing Screen to be sure the slots are clear of mineral build up To clean scrub with a calcium dissolving solve...

Page 7: ..._________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________...

Page 8: ...l Air Support directly at support ideal air com or call 1 877 9 IDEAL 1 Product not working properly DO NOT return this product to the store where you purchased it For answers to most common questions and a complete technical support library please visit www ideal air com cifications herein are subject to oduct improvement Contact Id ls updates and other informatio most common questions an t libra...

Reviews: