REFRIGERATED DISPLAY CASES
Units without their own cooling unit must be installed exclusively by an authorised refrigeration company.
NOTE
All units are equipped with coated fin coil evaporators. The connection pipes lead out downwards through the foamed refrigerated
well. All pipes are installed and insulated. Units that are configured with gas dampers for the opened position of the fin coil evapo
-
rator must be checked monthly to ensure they are working (depending on the model).
2.3.2. REFRIGERATION-RELATED INFORMATION
Solenoid valves, filter dryers and if applicable back pressure regulators must be installed by the customer.
NOTE
Various dangers when disposing of refrigerants
When disposing of refrigerants (propane, R404A, R134A etc.), wear protective gloves and safety glasses. Working with open
flames is forbidden during the disposal of refrigerant. Dispose of the refrigerant properly and in an environmentally compatible
way. The laws of the specific country must be observed.
Various dangers during the disposal of damaged parts/components
When disposing of damaged parts/components, wear protective gloves. Dispose of damaged parts/components properly
and in an environmentally compatible way. The laws of the specific country must be observed.
On self-contained units, the pipework is attached permanently to the refrigeration unit, and the refrigeration
circuit is filled with refrigerant. Display cases with expansion valves and those above a specific size have an
inspection glass with a moisture indicator (for checking during servicing). This is located beside the con
-
denser. There is no inspection glass for self-contained units with propane (R290) as a refrigerant.
Self-contained units
Remote refrigeration units are intended for connection to an existing refrigeration plant provided by the customer. The copper
tubing is insulated and leads out downward through the foamed refrigerated well with convection cooling. The evaporators are
equipped with an expansion valve for the desired refrigerant and filled with dry nitrogen. The specified evaporation temperatures
and the condensing temperatures must be kept constant. Steam components must be avoided in front of the expansion valve.
Remote refrigeration units
WARNING
WARNING
All work, installations, deliveries and services may only be carried out by authorised refrigeration companies and qualified speci
-
alists. The state of the art, relevant legal provisions, regulations and guidelines of authorities, professional and trade associations
must be complied with. The installed refrigeration system must be put into operation and a functional and safety test performed.
The report must be submitted to the operator.
Connection work
For servicing purposes, the refrigeration system including the stainless steel housing can be pulled out
to the front (customer side).
Do not pull or damage the lines behind it.
CAUTION
Summary of Contents for AKV Series
Page 1: ...Betriebsanleitung K HLVITRINEN Original 21A...
Page 2: ...Technische nderungen vorbehalten G ltig ab Juli 2021 2...
Page 25: ...Technische nderungen vorbehalten G ltig ab Juli 2021 25 NOTIZEN...
Page 39: ...Technische nderungen vorbehalten G ltig ab Juli 2021 39 NOTIZEN...
Page 57: ...Technische nderungen vorbehalten G ltig ab Juli 2021 57 NOTIZEN...
Page 81: ...Technische nderungen vorbehalten G ltig ab Juli 2021 81 NOTIZEN...
Page 83: ......
Page 85: ...Operating Manual REFRIGERATED DISPLAY CASES Translation of the original 21A...
Page 86: ...Subject to technical changes Valid from July 2021 2...
Page 109: ...Subject to technical changes Valid from July 2021 25 NOTES...
Page 123: ...Subject to technical changes Valid from July 2021 39 NOTES...
Page 141: ...Subject to technical changes Valid from July 2021 57 NOTES...
Page 165: ...Subject to technical changes Valid from July 2021 81 NOTES...
Page 167: ......