REFRIGERATED DISPLAY CASES
02
Variant 1
Top view of variant 1
Top view of variant 2
Variant 2
Oper
at
or side
Cust
omer side
Oper
at
or side
Cust
omer side
Compressor:
The compressor pumps the gaseous refrigerant through the cooling system.
Condenser/fan/blower:
The fan draws in cold ambient air by means of which it cools the compressor and the
hot gas in the condenser.
Condenser:
This is a heat exchanger in which the extracted heat of the cooling area is output back into the
circulating air. Gaseous refrigerant is liquefied again through the heat output. All self-contained
units have a pull-out compressor housing (condensing unit). This provides the option of positio
ning the condenser on the ventilation grille of the air inlet, and preventing air circulation.
Definition of Terms:
Air ba
ffle
Supply air
Exhaust air
2.7.
VENTILATION AND DISCHARGE
By default, the units are delivered with incoming air on the operator side and exhaust air on the customer side. We recommend
having the exhaust air outlet on the customer side (see variant 1). If an exhaust air outlet on the customer side is not possible,
then the exhaust air must discharge on the side of the unit or the operator side (see variant 2). Ensure that the exhaust air is
not directly drawn back in, in order to ensure perfect operation (of the cooling).
Reduction of the cooling capacity or destruction from overheating of the refrigeration unit
The air circulation openings of the refrigeration unit must not be blocked or obstructed. The airflow must not be interrupted
or impaired. The ventilation grilles must be at least 1.5-times the cross-section of the surface area of the condenser. The
openings in the ventilation grille should be executed with louvres.
CAUTION
Summary of Contents for AKV Series
Page 1: ...Betriebsanleitung K HLVITRINEN Original 21A...
Page 2: ...Technische nderungen vorbehalten G ltig ab Juli 2021 2...
Page 25: ...Technische nderungen vorbehalten G ltig ab Juli 2021 25 NOTIZEN...
Page 39: ...Technische nderungen vorbehalten G ltig ab Juli 2021 39 NOTIZEN...
Page 57: ...Technische nderungen vorbehalten G ltig ab Juli 2021 57 NOTIZEN...
Page 81: ...Technische nderungen vorbehalten G ltig ab Juli 2021 81 NOTIZEN...
Page 83: ......
Page 85: ...Operating Manual REFRIGERATED DISPLAY CASES Translation of the original 21A...
Page 86: ...Subject to technical changes Valid from July 2021 2...
Page 109: ...Subject to technical changes Valid from July 2021 25 NOTES...
Page 123: ...Subject to technical changes Valid from July 2021 39 NOTES...
Page 141: ...Subject to technical changes Valid from July 2021 57 NOTES...
Page 165: ...Subject to technical changes Valid from July 2021 81 NOTES...
Page 167: ......