GENERAL INFORMATION AND SAFETY
REFRIGERATED DISPLAY CASES
01
The following safety provisions and obligations apply generally when working with the unit:
•
Covers provided with warning signs may only be opened by authorised specialists.
•
The bottom and back of the unit must not be cleaned with a water jet.
•
The protective covers and protective devices may not be removed, otherwise there is a risk of injury.
•
The controller may only be opened by an authorised specialist.
•
Air flows in the area of the unit from improperly installed ventilation (e.g. air conditioners) or draughts must be prevented
in order to ensure perfect operation of the unit.
•
The ambient temperature must not 25 °C, and the relative ambient humidity must not exceed 60%.
•
The unit is not suitable for operation in entrance and outdoor areas.
•
The unit must be protected against direct sunlight.
•
The products being presented must be pre-cooled and placed into the unit with a core temperature of the desired tem
-
perature class or colder.
•
No loose sharp objects must be kept in the unit, otherwise there is a risk of injury.
•
All glass enclosures must be treated with the necessary care in order to prevent injuries from breaking glass.
•
Components and service fluids may only be replaced with original parts.
•
Do not store any combustible or explosive products in the unit or close to it.
•
During the assembly and/or installation, the unit must be covered adequately so that no contact with live parts is
possible.
•
The installation environment must be robustly constructed in order to withstand the strains of everyday operation.
•
It must not be possible to remove any coverings that are mounted during the installation without tools.
•
After cleaning, service or maintenance, the unit must be checked for loose connections, shearing points and damage.
Remedy any deficiencies that are discovered immediately. Do not use the unit for any non-designated purposes.
•
When topping up refrigerant, only the refrigerant stated on the rating plate (identification plate) may be used.
•
Topping-up may only be performed by authorised specialists. The filling quantity stated on the rating plate must be
followed.
•
The unit must be installed away from heat sources in a low-dust and well-ventilated environment.
•
Pushing or moving the unit is not permitted. Units must be lifted for transport or relocation (depending on the model).
Technical changes to the unit may only be carried out by authorised specialists. This applies in particular to work on
the refrigeration system, electrical installation and mechanics.
Any change must be authorised by your supplier or the manufacturer.
The unit must not be operated in the immediate vicinity of devices that generate heat or steam. This can result in compres
-
sor damage, the formation of condensate on the glass, temperature control problems in the cooling area etc.
NOTE
NOTE
1.8.
GENERAL SAFETY INSTRUCTIONS
Summary of Contents for AKV Series
Page 1: ...Betriebsanleitung K HLVITRINEN Original 21A...
Page 2: ...Technische nderungen vorbehalten G ltig ab Juli 2021 2...
Page 25: ...Technische nderungen vorbehalten G ltig ab Juli 2021 25 NOTIZEN...
Page 39: ...Technische nderungen vorbehalten G ltig ab Juli 2021 39 NOTIZEN...
Page 57: ...Technische nderungen vorbehalten G ltig ab Juli 2021 57 NOTIZEN...
Page 81: ...Technische nderungen vorbehalten G ltig ab Juli 2021 81 NOTIZEN...
Page 83: ......
Page 85: ...Operating Manual REFRIGERATED DISPLAY CASES Translation of the original 21A...
Page 86: ...Subject to technical changes Valid from July 2021 2...
Page 109: ...Subject to technical changes Valid from July 2021 25 NOTES...
Page 123: ...Subject to technical changes Valid from July 2021 39 NOTES...
Page 141: ...Subject to technical changes Valid from July 2021 57 NOTES...
Page 165: ...Subject to technical changes Valid from July 2021 81 NOTES...
Page 167: ......