After resetting the temperature some time needs to pass before the desired temperature has been achieved.
Please check the interior temperature a few hours afterwards with an exact thermometer and reset the thermostat
if needed.
Depending on the surrounding temperature and humidity, the interior temperature is not to be set too low as this
could lead to icing on exposed areas of the cooling element. This will interfere with the cooling performance and
with the continuous defrosting which has been set by your specialized dealer for a certain interval.
6.4. Automatic defrosting
Automatic defrosting takes place via the electronic thermostat and is fully automatically controlled.
The defrosting process takes maximum 30 minutes. Defrost cycles are pre-programmed and starts every 3 hours
(self serve displays) or 2 hours (displays for assited service). Cooling mode starts automatically after the end of
defrost mode.
6.5. Manual defrosting
Defrosting can be started any time by pressing the UP - button (
1
) for three seconds. During the process of defros-
ting the respective LED is illuminated. The LED flashes if defrosting is requested, but may not be started yet due
to interlock conditions.
6.6. Lighting
Lighting of the Display case is connected to the control unit and is then switched ON/OFF by pressing the LIGHT
button (
3
) on the controller display.
7. Loading restrictions
Load the display case with pre-chilled product from the rear doors. You can place the goods on the glass shelves
and on the base decks. BRILLANT models have a deep well with height adjustable base decks. The display case
is designed to maintain the temperature of pre-chilled product!
This refrigerated unit is not a refrigerator, and consequently, if warm product is introduced, there could be a con-
siderable delay before the operating temperature falls to the normal operating level.
Don‘t overload the cabinet with too much products. It is important to leave adequate free space for the refrigerated
air to circulate within the display case. Product should be kept clear of the shaded areas, shown in the picture
below. Consider the
maximum load for shelves and base decks
, shown on the next page!
R
Correct Loading
Q
Wrong Loading
Cold air curtain is not
affected or blocked by
goods !
Optimum refrigeration
and presentation of the
goods!
Air flow is blocked
and refused through
too
much
goods!
Ineffectiv
refrigeration
and confusing presenta-
tion of the goods!