Mexico Super CF 3/60P - 3/140P -
Installation
Boiler Size
CF 3/60P
CF 3/75P
CF 3/100P
CF 3/125P
CF 3/140P
Gas Supply Connection
in. BSP
Rc 1/2 (1/2)
Rc 3/4 (3/4)
Number of Boiler Sections
3
3
4
5
6
Flow and Return Connections
Rc 1 (1" BSP)
MAXIMUM Static Water Head
m (ft.)
30.5 (100)
(3 bar)
MINIMUM Static Water Head
m (ft.)
1.0 (3.3)
Electrical Supply
230 V ~ 50 Hz
External Fuse Rating (Power Consumption)
3 A
(5 W)
Water Content
litre (gal.)
7.4 (1.6)
7.4 (1.6)
9.8 (2.1)
12.2 (2.7)
14.6 (3.2)
Dry Weight
kg. (lb.)
89 (196)
89 (196)
111 (245)
134 (295)
157 (346)
Boiler Size
Height
mm (in.)
850 (33.5)
Width
mm (in.)
440. (17.4)
Depth
mm (in.)
533 (21.0)
533 (21.0)
533 (21.0)
600 (23.6)
750 (29.5)
Gas Type
II
2H 3P
Flue Connection
mm (in.)
100 (4)
125 (5)
150 (6)
Table 1 - Boiler Data
GENERAL
Boiler Size
CF 3/60P
CF 3/75P
CF 3/100P
CF 3/125P
CF 3/140P
Boiler Input
NOMINAL
kW (Btu/h)
22.1 ( 75 400)
27.3 (93 100)
35.8 (122 100) 43.4 (148 100) 53.5 (182 500)
Gas Consumption
l/s (ft.
3
/h)
0.246 (31.8)
0.287 (37.1)
0.377 (48.8)
0.457 (59.2)
0.563 (72.9)
Boiler Output to Water
NOMINAL
kW (Btu/h)
18.1 (61 600)
22.2 (75 800)
29.3 (100 000) 35.6 (121 600) 44.3 (151 100)
Burner Setting Pressure (hot)
NOMINAL
mbar (in w.g.)
35.4 (14.2)
35.0 (14)
35.0 (14)
35.1 (14)
34.9 (14)
Inlet Pressure
NOMINAL
mbar (in w.g.)
37.0 (14.8)
37.0 (14.8)
37.0 (14.8)
37.0 (14.8)
37.0 (14.8)
Flue Gas Flow Rate
g/s
10.6
13.1
17.2
20.8
25.7
Flue Gas Temperature
o
C
125
134
129
140
132
Seasonal Efficiency(SEDBUK)
*
%
72.7
72.3
72.0
72.8
73.0
Table 2 - Performance Data
Notes.
1.
Gas consumption is calculated using a calorific value of 95.0
MJ/m
3
(2500 Btu/ft.
3.
)
2.
To obtain the fuel consumption in liquid form divide the above
figures by 270.
3.
The appliance is pre-set at the factory to give the nominal
output at an inlet pressure of 37 mbar (14.8 in.w.g.)
4.
A conversion kit is available to convert this appliance for use
on natural gas. This kit contains all parts and istructions for
setting up on natural gas. Once converted it is not possible
to convert back to propane.
Key to symbols
GB
= United Kingdom
IE
= Ireland (Countries of destination)
PMS
= Maximum operating pressure of water
B
11BS
= An appliance designed for connection to a flue
discharging the products of combustion outside the room,
with air for combustion being drawn directly from the
room where the appliance is installed, without a fan in
the combustion products circuit and fitted with a
combustion products discharge safety device.
II
2H3P
= An appliance designed for use on 2nd Family gas, Group
H and 3rd Family gas, Group P.
*
The value is used in the UK government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by BGplc 0087)
Summary of Contents for 4134899