INSTALLATION
14
Buccaneer GT Range
- Installation
BOILER
It is not advisable to drain an installation, except in case of
absolute necessity. Check regularly the water level of the
installation and top it up if necessary, avoiding a sudden inlet
of cold water into the hot boiler.
This operation should only be done a few times a year;
otherwise, look for the leakage and remedy it without delay.
The good performance of the boiler depends on its
degree of cleanliness.
Cleaning of the boiler must be carried out as often as
required and at least, as for the chimney, once a year or
more, according to the regulations in force.
The following operations are always carried out with the
boiler and the power supply shut off.
Cleaning of the flue gas circuit:
For this purpose:
- Remove the front cover
- Open the door by unscrewing the four locknuts
(13mm spanner)
9
MAINTENANCE
Data plate
Week
01-52
Year
01=1991
02=1992
X X - X X
Manufacturing year code