ASSEMBLY
8
Fitting of the insulation for the main casing, the panel and the upper section:
Place the front panel insulation in the space provided under the control panel.
Pass the strap (3 section boilers) or both straps (4 & 5 boilers) under the boiler body.
Place the wide part (with cut-out for the feet) of the insulation panels of the heat body between the base and the main casing
and fix them under the control panel using the 2 fixings.
Tighten the insulation around the casing by pulling the strap(s).
8199-EN-35
Wiring of burner cable and fitting of side panels
Open the panel (2 screws plus toothed washers)
Fit the burner cable, on the side opposite to the burner door
hinge (according to European safety regulations) and pass it
through the outside of the crosspiece.
Fit the panel into the base and hook it onto the screw °3,94 x
12,7 and the toothed washer already fitted behind the control
panel (3 section boilers) or the rear crosspiece (4 & 5 section
boilers) and tighten it.
Fix the front panels to the control panel using 2 screws ø 3,94
x 12,7 and 2 toothed washers ø 4 - ready supplied.
8199-EN-36
8199-EN-37 A
Securing the burner cable
Pass the burner wire behind the side panel towards the burner
keeping it in position using the cable holder supplied (see
diagram). Adjust the length of the cable so that it will need to
be disconnected when the burner door is opened. Slide the
surplus cable to the back between the insulation and the side
panel.
8199-EN-38 A