INSTALLATION
38 DEACTIVATING THE DOMESTIC HOT WATER PRIORITY
2
4
3
3
2
1
buc5523
buc55
24
5
buc5525
7
6
When the domestic hot water priority is deactivated, heating is
no longer cut off during domestic hot water heating phases.
-
Switch off the boiler power supply.
-
Remove the front panel proceeding as follows:
1.
Lift the control panel cover.
2.
Unscrew the two front panel side attachment screws.
3.
Pull the front panel clear from the clips and the notches in
the top part, pulling it towards you.
4.
Remove the front panel from the notches near the bottom
of the side panels.
5.
Unscrew the attachment screw fastening the front of
the control panel.
6.
Tilt the front panel.
7.
Remove the shunt (bridge).
8.
Close the control panel and put the front panel
back into position, using the same procedure as
for disassembly in the reverse order.
39 HEATING PUMP OVERRUN
The heating pump overrun is fixed at 12 minutes after the room thermostat is satisfied or changing to summer mode.
40 FUEL OIL OR GAS CONNECTIONS
Refer to the instructions supplied with the burner.