24
Mexico Super CF 3/100, 3/125, 3/140 -
Installation
36 GENERAL
1.
Disconnect the ignition lead from the piezo unit body.
2.
Remove the retaining nut and withdraw the unit, as
shown.
3.
Fit the new unit and reassemble in reverse order.
SERVICING
38 PIEZO UNIT REPLACEMENT
39 PILOT BURNER REPLACEMENT
1.
Lift off front panel and remove the grille assembly - refer
to Frames 28 & 29.
Undo the gas cock union and the 4 wing nuts to remove
the burner / controls assembly.
2.
Remove the ignition electrode . Refer to Frames 44 .
3.
Unscrew the thermocouple connection and pull the
thermocouple clear. Refer to Frame 45.
4.
Undo the pilot supply pipe connection and ease clear of
the pilot burner. DO NOT LOSE the pilot injector, which is
a push-fit in the pilot burner housing.
5.
Remove the 2 securing screws and washers, and
withdraw the pilot burner.
6.
Fit the new pilot burner and re-assemble in reverse order,
ensuring that:
a.
The injector is in position when refitting the pilot
supply.
b.
A gas-tight joint is made.
c.
The spark gap is correct. Refer to Frame 44.
When replacing any component:
1.
Isolate the electricity supply.
2.
Turn off the gas supply at the boiler.
3.
Remove the lower front panel .
For replacement of pumps or
programmer units refer to the
separate Pump Kit or Programmer
Kit instructions.
37 SIGHTGLASS REPLACEMENT
1.
Unfasten the 2 M5 hexagon nuts and washers. Remove
the assembly from the front plate.
2.
Fit the new sightglass
and re-assemble, as
shown.
3.
Retighten the 2 M5
hexagon nuts to ensure
an airtight
seal.
Do NOT
overtighten.
REPLACEMENT OF PARTS
SER
VICING
Summary of Contents for CF#/125
Page 1: ......