4
Classic FF 340 - 360 LF
-
Installation & Servicing
GENERAL
INTRODUCTION
The Classic FF340-360 LF are automatically fully controlled, wall
mounted, fanned gas boilers.
The heat exchanger is cast iron. The boiler casing is of white
enamelled mild steel.
The boiler casing has a removable controls pod containing a drop-
down door. The boiler thermostat is located behind the drop-down
door.
Note.
These boilers cannot be used on systems which include
gravity circulation. If gravity circulation is required the Classic RS
range of boilers is suitable.
See Frame 1 for details of the correct boiler tappings to use.
The boiler is supplied with a standard flue kit suitable for rear or
side outlet applications from 2.5m (98
1/2
") to 4.5m (176") with
the necessary extension ducts.
The boilers are suitable for connection to the following open
vented or sealed systems:
!
Fully pumped CH and indirect DHW
!
Pumped heating only.
!
Pumped indirect DHW only.
OPTIONAL EXTRA KITS
Downward Piping Kit.
Programmer Kit.
90°
Flue Elbow Kit
Ideal Sealed System Unit - this fits on top of the appliance.
Suitable for standard boiler only.
Extension ducts
-
up to 4.5m (176").
Turret Outlet Kit.
BS.6891
Low pressure installation pipes.
BS.6798
Installation of gas fired hot water boilers of rated input
not exceeding 70 kW.
BS.5449
Forced circulation hot water systems.
BS.5546
Installation of gas hot water supplies for domestic
purposes (2nd Family Gases).
BS.7593
Treatment of water in domestic hot water central
heating systems.
BS.5440.1 Flues for gas appliances of rated input not exceeding
70 kW.
BS.5440.2 Ventilation for gas appliances of rated input not
exceeding 70 kW.
Health & Safety Document No. 635
The Electricity at Work Regulations, 1989.
Manufacturer’s notes must NOT be taken in any way as overriding
statutory obligations.
IMPORTANT. These appliances are certificated by the British
Standards Institution for safety and performance. It is, therefore,
important that no external control devices, e.g. flue dampers,
economisers etc., are directly connected to these appliances -
unless covered by these Installation and Servicing instructions
or otherwise recommended by Caradon Ideal Limited in writing.
If in doubt please enquire.
Any direct reconnection of a control device not approved by
Caradon Ideal Limited could invalidate the BSI Certification and
the normal appliance warranty. It could also infringe the Gas
Safety Regulations and the above regulations.
SAFE HANDLING OF SUBSTANCES
Care should be taken when handling the boiler insulation panels
which can cause irritation to the skin. No asbestos, mercury or
CFCs are included in any part of this boiler.
LOCATION OF BOILER
The boiler must be installed on a flat and vertical wall, capable of
adequately supporting the weight of the boiler and any ancillary
equipment.
The boiler may be fitted on a combustible wall and insulation
between the wall and the boiler is not necessary - unless required
by the local authority. The boiler must not be fitted outside.
Timber Framed Buildings
If the boiler is to be fitted in a timber framed building it should be
fitted in accordance with the Institute of Gas Engineering document
IGE/UP/7:1998.
Bathrooms
This range of appliances is rated IP 1XB.
The boiler may be installed in any room or internal space, although
particular attention is drawn to the requirements of the current
I.E.E. (BS.7671) Wiring Regulations and, in Scotland, the electrical
provisions of the building regulations applicable in Scotland with
respect to the installation of the boiler in a room or internal space
containing a bath or shower. For Ireland reference should be made
to the current ETCI rules for electrical installations and
I.S.813:2002.
If the appliance is to be installed in a room containing a bath or
shower then, providing water jets are not going to be used for
cleaning purposes (such as communal baths/showers), the
appliance can be installed in Zone 3, as detailed in BS.7671.
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK
AND GIVE THIS TO THE CUSTOMER.
CURRENT GAS SAFETY (INSTALLATION AND USE)
REGULATIONS OR RULES IN FORCE.
The appliance is suitable only for installation in GB and IE and
should be installed in accordance with the rules in force.
In GB, the installation must be carried out by a CORGI
Registered Installer. It must be carried out in accordance with
the relevant requirements of the:
•
Gas Safety (Installation and Use) Regulations
•
The appropriate Building Regulations either The Building
Regulations, The Building Regulations (Scotland), Building
Regulations (northern Ireland).
•
The Water Fittings Regulations or Water byelaws in
Scotland.
•
The Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference should be
made to the relevant British Standard Code of Practice.
In IE, the installation must be carried out by a Competent
Person and installed in accordance with the current edition of
I.S.813 "Domestic Gas Installations", the current Building
Regulations and reference should be made to the current ETCI
rules for electrical installation.
Detailed recommendations are contained in the following British
Standard Codes of Practice:
......continued on page 6.