4
GENERAL
Classic
Slimline FF
-
Installation & Servicing
INTRODUCTION
The Classic Slimline FF330-360 is a range of automatically fully
controlled, wall mounted, balanced flue, fanned gas boilers.
The heat exchanger is cast iron. The boiler casing is of white
enamelled mild steel.
The boiler casing has a removable controls pod containing a drop-
down door. The boiler thermostat is located behind the drop- down
door.
Note.
These boilers cannot be used on systems which include
gravity circulation. If gravity circulation is required the Classic RS
range of boilers is suitable.
See Frame 1 for details of the correct boiler tappings to use.
The boilers are supplied with a standard flue kit suitable for rear or
side outlet applications from 114 mm (4
1/2
") to 600 mm
(23
1/2
").
The boilers are suitable for connection to the following open
vented or sealed systems:
!
Fully pumped CH and indirect DHW
!
Pumped heating only.
!
Pumped indirect DHW only.
OPTIONAL EXTRA KITS
Extension duct
-
up to 1m (39").
BS.5449
Forced circulation hot water systems.
BS.5546
Installation of gas hot water supplies for domestic
purposes (2nd Family Gases).
BS.7593
Treatment of water in domestic hot water central
heating systems.
BS.5440.1 Flues for gas appliances of rated input not exceeding
70 kW.
BS.5440.2 Ventilation for gas appliances of rated input not
exceeding 70 kW.
Health & Safety Document No. 635
The Electricity at Work Regulations, 1989.
Manufacturer’s notes must NOT be taken in any way as overriding
statutory obligations.
IMPORTANT. These appliances are certificated by the BG
Technology Certification Services for safety and performance. It
is, therefore, important that no external control devices, e.g. flue
dampers, economisers etc., are directly connected to these
appliances -unless covered by these Installation and Servicing
instructions or otherwise recommended by Caradon Ideal
Limited in writing. If in doubt please enquire.
Any direct reconnection of a control device not approved by
Caradon Ideal Limited could invalidate the certification and the
normal appliance warranty. It could also infringe the Gas Safety
Regulations and the above regulations.
SAFE HANDLING OF SUBSTANCES
Care should be taken when handling the boiler insulation
panels, which can cause irritation to the skin. No asbestos,
mercury or CFCs are included in any part of the boiler.
LOCATION OF BOILER
The boiler must be installed on a flat and vertical wall, capable
of adequately supporting the weight of the boiler and any
ancillary equipment.
The boiler may be fitted on a combustible wall and insulation
between the wall and the boiler is not necessary - unless
required by the local authority. The boiler must not be fitted
outside.
Timber Framed Buildings
If the boiler is to be fitted in a timber framed building it should be
fitted in accordance with the Institute of Gas Engineering
document IGE/UP/7:1998.
Bathrooms
The boiler may be installed in any room or internal space,
although particular attention is drawn to the requirements of the
current I.E.E. (BS.7671) Wiring Regulations and, in Scotland, the
electrical provisions of the building regulations applicable in
Scotland with respect to the installation of the boiler in a room or
internal space containing a bath or shower. For Ireland
reference should be made to the current ETCI rules for electrical
installations and I.S. 813: 2002.
......continued on page 6.
CURRENT GAS SAFETY (INSTALLATION AND USE)
REGULATIONS OR RULES IN FORCE.
The appliance is suitable only for installation in GB and IE and
should be installed in accordance with the rules in force.
In GB, the installation must be carried out by a CORGI
Registered Installer. It must be carried out in accordance with
the relevant requirements of the:
•
Gas Safety (Installation and Use) Regulations
•
The appropriate Building Regulations either The Building
Regulations, The Building Regulations (Scotland), Building
Regulations (northern Ireland).
•
The Water Fittings Regulations or Water byelaws in
Scotland.
•
The Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference should be
made to the relevant British Standard Code of Practice.
In IE, the installation must be carried out by a Competent
Person and installed in accordance with the current edition of
I.S.813 "Domestic Gas Installations", the current Building
Regulations and reference should be made to the current ETCI
rules for electrical installation.
Detailed recommendations are contained in the following British
Standard Codes of Practice:
BS.6891
Low pressure installation pipes.
BS.6798
Installation of gas fired hot water boilers of rated
input not exceeding 60 kW.
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK AND
GIVE THIS TO THE CUSTOMER.