Classic
LXRS, RS
-
Propane Installation
3
Boiler Size
RS 245 P
RS 255 P
Gas supply connection
Rc 1/2 (1/2)1/2" (BSP Female)
Flow connection
22mm copper
Return connection
22mm copper
Maximum static water head
m (ft.)
30.5 (100)
Minimum static water head
m (ft.)
0.45 (1.5)
Electrical supply
230 V ~ 50 Hz
Fuse rating
External; 3A
Water content
litre (gal.)
3.65 (0.8)
4.6 (1.0)
Dry Weight
Deluxe model
kg (lb)
49.3 (108.7)
57.2 (126.1)
Standard model
kg (lb)
46.3 (102.1)
54.2 (119.5)
Maximum installation weight
kg (lb)
34.7 (76.5)
42.7 (94.2)
Boiler size
Height
mm (in.)
600 (23.6)
600 (23.6)
Width
mm (in.)
380 (15.0)
380 (15.0)
Depth
mm (in.)
Deluxe 315 (12
3/8
")
Standard 300 (11
3/4"
)
Boiler Size
RS 245 P
RS 255 P
Boiler input
kW
16.5
20.1
(Btu/h)
(56 250)
(68 600)
Gas consumption
l/s (ft
3
/h)
0.17 (22.5)
0.21 (27.5)
Boiler output
kW
13.2
16.1
(Btu/h)
(45 000)
(55 000)
Burner Setting
mbar
35.8
35.7
pressure (HOT)
(in.w.g.)
(14.3)
(14.3)
Inlet pressure
mbar (in.w.g.)
37.0 (14.8)
37.0 (14.8)
Seasonal Efficiency (SEDBUK) *
%
72.2
71.1
Table 1 - General Data
GENERAL
Table 2 - Performance Data
To obtain the gas consumption:
a.
For l/s divide heat input (kW) by C.V. of the gas (MJ/m
3
)
b.
For ft
3
/h divide heat input (Btu/h) by C.V. of the gas (Btu/ft
3
)
*The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by BGplc 0087.
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK
AND GIVE THIS TO THE CUSTOMER.