2
Classic RS -
Installation & Servicing
GENERAL
Boiler Size
RS 330
RS 340
RS 350
RS 360
Boiler input
kW
10.9
14.5
17.8
21.7
(Btu/h)
(37 200)
(49 500)
(60 750)
(74 000)
Gas consumption l/s (ft
3
/h)
0.28 (36.1)
0.38 (48.2)
0.46 (58.6)
0.56 (71.3)
Boiler output
kW
8.8
11.7
14.7
17.6
(Btu/h)
(30 000)
(40 000)
(50 000)
(60 000)
Burner setting pressure (HOT)
mbar (in.w.g.)
6.4 (2.6)
11.0 (4.4)
13.1 (5.3)
14.1 (5.7)
Seasonal Efficiency (SEDBUK)*
Band D
[78.4]%
[78.9]%
[80.3]%
[79.0]%
Boiler Size
RS 330
RS 340
RS 350
RS 360
Gas supply connection
Rc
1/2
(
1/2
)
1/2
" (BSP Female)
Flow connection
22mm copper
Return connection
22mm copper
Maximum static water head
m (ft.)
30.5 (100)
Minimum static water head
m (ft.)
0.45 (1.5)
Electrical supply
230 V 50 Hz
Fuse rating
External: 3A
Water content
litre (gal.)
3.65 (0.8)
4.6 (1.0)
Dry Weight
kg (lb.)
46.3 (107.1)
54.2 (119.5)
Maximum installation weight
kg (lb.)
34.7 (76.5)
42.7 (94.2)
Boiler size
Height
mm (in.)
600 (23.6)
Width
mm (in.)
380 (15.0)
Depth
mm (in.)
300 (11
3/4
")
Table 1 - General Data
Table 2 - Performance Data
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of this
appliance, care should be taken when handling edges of sheet steel components
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by a notified body.
To obtain gas consumption
(a) For l/s: divide heat input (kW) by C.V. of the gas (Btu/ft
3
)
(b) For ft
3
/h; divide by C.V. of the gas (Btu/ft
3
).
Heat inputs are preset to the highest nominal rating.