IMPORTANT.
The gas service cock is sealed with a non-metallic blue fibre washer, which must not be overheated when
making capillary connections. Refer to Frame 2 for details of the position of the gas connection.
A boiler gas supply pipe length of 20m and not less than 15mm O.D. can be connected to the boiler via the gas service
cock union.
Ensure that the gas supply pipe does not foul the boiler casing.
For additional gas supply information refer to ‘Gas Supply’ on page 8.
34 GAS CONNECTION
The safety valve connection, located at the bottom right-hand side of the boiler, comprises a 15mm diameter stub pipe.
The discharge pipe should be positioned so that the discharge of water or steam cannot create a hazard to the occupants
of the premises or damage the electrical components and wiring. A 15mm compression fitting is supplied with the
Hardware Pack to connect it to the stub pipe.