Classic Slimline FF -
User's
To light the boiler
.
Refer to Frame 1
1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.
2. Open the controls access door by hinging downwards.
3. Ensure that the gas inlet cock (B) is OPEN.
4. Press the overheat reset button (D), located as shown in
Frame 1.
5. Ensure that the mains on/off switch (E) is in the OFF position.
6. Switch ON the electricity supply to the boiler. Check that all
external controls, e.g. room thermostat etc., are ON.
7. Turn the boiler thermostat knob (C) to position 6 and the mains
on/off switch (E) to ON. After about 15 seconds the boiler will
light automatically - this can be viewed through the sight glass
(A). Set the boiler thermostat to the desired position.
8. Close the controls access door.
In winter conditions, i.e. central heating and domestic hot water,
the thermostat should be set at position 5 or 6.
For summer conditions, i.e. domestic hot water only, the
thermostat should be set at position 3.
These settings, however, are offered for general guidance only
and other settings may be found preferable, dependent upon the
type of system installed or as recommended by the installer.
Approximate flow temperatures for the boiler thermostat settings
are:
CLASSIC SLIMLINE FF
(
Natural Gas Models Only)
Current Gas Safety (Installation &
Use) Regulations or rules in force.
In your own interest, and that of safety, it is the law that this boiler
must be installed by a CORGI registered installer or in IE a
competent person, in accordance with the above regulations.
Electricity supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a
plug and socket, serving only the boiler and system controls.
The means of isolation must be accessible to the user after
installation.
Important notes
a.
This appliance must not be operated without the casing correctly
fitted and forming an adequate seal.
b.
If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.
c.
The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically that
the ventilation areas are free from any obstruction.
d.
If it is known or suspected that a fault exists on the boiler then it
MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.
e.
Inflammable materials must not be placed in close proximity
to the appliance. Materials giving off flammable vapours must
not be stored in the same room as the appliance.
f.
Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.
Minimum clearances
After the removal of any concealment panel a clearance of 533mm
(21") MUST be available at the front of the boiler for servicing.
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components
Classic Slimline FF 330 ............. G.C. No. 41 392 02
Classic Slimline FF 340 ............. G.C. No. 41 392 03
Classic Slimline FF 350 ............. G.C. No. 41 392 04
Classic Slimline FF 360 ............. G.C. No. 41 392 05
The following minimum clearances MUST be complied with in
order to maintain the safe running of the boiler and to facilitate
servicing.
Above the boiler
100 mm
(4")
At each side of the boiler
5 mm
(
1/4
")
Underneath the boiler
100 mm
(4")
In front of the boiler
5 mm
(
1 /4
")
Knob Setting
Flow Temperature
°C
°F
1
56
133
2
61
142
3
66
152
4
72
161
5
77
170
6
82
180
Introduction
It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of the
boiler.