3
Henrad SE FF
- Installation
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.
Boiler Size
SE 30 FF
SE 40 FF
SE 50 FF
SE 60 FF
SE 70 FF
SE 80 FF
Boiler input
Nett
kW
9.2
12.3
15.3
18.4
21.5
24.6
CV
Btu/h
31,400
42,000
52,200
62,800
73,400
84,000
Boiler input
Gross
kW
10.2
13.6
17.0
20.4
23.9
27.3
CV
Btu/h
34,900
46,500
58,100
69,800
81,400
93,000
Gas consumption
l/s (cu.ft/h)
0.26 (33.6) 0.35 (44.9) 0.44 (56.1) 0.53 (67.3) 0.62 (78.6) 0.70 (89.8)
Boiler output
70 °C Mean water
kW
8.8
11.7
14.7
17.6
20.5
23.4
temperature
Btu/h
30,000
40,000
50,000
60,000
70,000
80,000
40 °C Mean water
kW
9.4
12.5
15.7
18.8
21.9
25.1
temperature
Btu/h
32,100
42,800
53,500
64,200
74,900
85,600
Burner Setting
mbar
10.7
10.0
8.6
10.5
5.3
8.8
pressure (HOT)
in.w.g.
4.3
4.0
3.5
4.2
2.1
3.5
Seasonal efficiency (SEDBUK)*
[86.1]%
[86.7]%
[86.4]%
[86.3]%
[86.5]%
[86.3]%
Boiler Size
SE 30 FF
SE 40 FF
SE 50 FF
SE 60 FF
SE 70 FF
SE 80 FF
Gas supply connection
(in. BSP)
Rc
1/2
(
1/2
" BSP Female)
Flow connection
22mm copper (via adaptors
28mm copper
(FEMALE)
supplied)
(MALE)
Return connection
22mm copper
(via adaptors
28mm copper
(FEMALE)
supplied)
(MALE)
Maximum static water head
m (ft.)
30.5 (100)
Minimum static water head
m (ft.)
0.45 (1.5)
Electrical supply
230 V ~ 50 Hz
Boiler power consumption
50W
Fuse rating
External: 3A
Internal: F2A to BS 4265
Water content
litre (gal.)
1.65 (0.36)
1.95 (0.43)
Dry Weight
kg (lb.)
26.0 (57.3)
27.0 (59.5)
Boiler size
Height
mm (in.)
600 (23.6)
Width
mm (in.)
390 (15.0)
Depth
mm (in.)
270 (10.6)
Flue duct diameter
mm (in.)
100 (4.0)
GENERAL DATA
Table 2 - Performance Data
Table 1 - Boiler Data
Notes.
To obtain the gas consumption:-
a. For l/s divide the gross heat input (kW) by C.V. of the gas (MJ/m
3
)
b. For ft
3
/h divide the gross heat input (Btu/h) by C.V. of the gas (Btu/ft
3
)
*The value used is in the UK government's Standard Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been calculated have been certified by BGplc 0087.
Summary of Contents for Henrad SE 30 FF
Page 1: ......