34
icos system condensing -
Installation and Servicing
SERVICING
54 BURNER INJECTOR REPLACEMENT
1.
Refer to Frame 51.
2.
Remove the boiler sealing panel - Refer to Frame 44.
3.
Disconnect the electrical leads from the fan.
4.
Undo the gas pipe union connection to the injector
housing.
5.
Remove the retaining screw and pull off the mounting
bracket.
6.
Remove the fan and venturi assembly.
7.
Remove the 2 injector housing retaining screws.
8.
Withdraw the injector housing.
9.
Fit the new injector housing complete with injector.
10.
Re-assemble in reverse order, ensuring that the new gas
seal supplied is located correctly in the injector housing.
11.
Check operation of the boiler. Refer to Frame 51.
55 SIGHT GLASS REPLACEMENT
1.
Refer to Frame 51.
2.
Remove the boiler sealing panel - Refer to Frame 44.
3.
Unscrew the 2 sight glass retaining screws.
4.
Remove the sight glass, gasket and bracket.
5.
Fit new sight glass, using the new bracket and gasket
supplied.
6.
Re-assemble in reverse order.
7.
Check operation of the boiler. Refer to Frame 51.
56 BURNER REPLACEMENT
1.
Refer to Frame 51.
2.
Remove the boiler sealing panel - Refer to Frame 44.
3.
Remove the fan - Refer to Frame 53.
4.
Remove the 6 securing screws and lift the burner off the
combustion chamber.
5.
Fit the new burner, replacing any damaged or deteriorating
sealing gasket.
6.
Re-assemble in reverse order.
7.
Check the operation of the boiler. Refer to Frame 51.
Note.
Take care not to disturb the detection earth probe at the rear
of the combustion chamber.
Gas pipe union
Fan
Retaining
screw
Injector
Retaining
screw
Mounting bracket
Ecl 2102
Retaining
screw
2107
Retaining screws
Gasket
Sightglass
Bracket
Ecl 2021
Securing
screws
Burner
Sealing
gasket
Detection
earth
probe
SER
VICING