24
INsTaLLaTION
Ideal Logic Code Combi -
Installation and Servicing
FLUE OUTLET
25 CONNECTINg ThE FLUE TO ThE BOILER
Notes.
• Before fitting the flue turret fill the condensate
trap within the boiler by pouring a cupful of
water into the flue outlet.
Take care to ensure
that the water is only poured into the flue outlet,
and does not spill into the boiler casing.
• During assembly check that flue seals do not
become dislodged.
1.
Ensure front panel is removed.
Refer to Frame 9.
2.
Locate the flue into the turret.
3.
Insert the flue assembly through
the prepared hole in the wall. Push
through and pull back to seal against
outside wall face.
4.
Ensure rubber flue seal is present
& fully engaged into plastic top flue
manifold then locate the flue turret
into the flue manifold and secure by
applying downward pressure.
5.
Engage the clamp in its slide
mechanism and push it horizontally
backwards
6.
Fit the previously removed screw
fixing.
Note - Flues over 1 metre long
It is recommended that a support
bracket is fitted for every 1 metre of
extension pipe used and a bracket
should be used at every joint, to ensure
pipes are held at the correct angle.
2
3G9847a
3
3G9847b
206279-10263
5
206279-10264
Retaining Clip
(assembled)
6
Flue Outlet
4
10120-204626
noTe. siDe Flue
Select the orientation
before inserting turret into
boiler flue manifold.
DO NOT twist the turret
once inserted.
206279-1.indd 24
06/01/2011 09:10:09