SERVICING
30
Mexico Slimline CF440 -
Installation & Servicing
46 TTB DOWNDRAUGHT THERMOSTAT REPLACEMENT
1.
Refer to Frame 35.
2.
Remove the control panel. Refer to Frame 29.
3.
Remove the securing screws and lift off the
control box cover.
4.
Unplug the in-line connector to the TTB
thermostat.
Note.
The
TTB thermostat is located at the LH side of
the diverter panel.
5.
Reach down the side of the boiler and carefully
lift the TTB bracket from its retaining slot and
clip.
6.
Withdraw the thermostat, bracket and lead
down the side of the boiler.
7.
Locate and fit the new TTB downdraught
thermostat, bracket and lead and reassemble
in reverse order, ensuring that the in-line
connector is secured.
1.
Refer to Frame 35.
2.
Remove the 2 screws and lift off the
lower front panel. Refer to Frame 29.
3.
Undo the PCB cover fixing screws
and remove the cover.
4.
Remove the HT lead from the PCB.
5.
Remove the 6 push-in connectors
from the PCB.
6.
Compress the barbs on the PCB
stand-offs to release the PCB from
the box
7.
Fit the new PCB and reassemble in
reverse order.
8.
Refit the boiler casing.
9.
Check the operation of the boiler.
47 PCB BOX REPLACEMENT
MEX 2299
PCB
PCB stand-off
3
SER
VICING
200946-1.p65
3/9/2004, 3:30 PM
30