32
Mexico Super CF 3/60P - 3/140P -
Installation
53 MAIN BURNER INJECTOR REPLACEMENT - CF 3/100P, CF 3/125P & CF 3/140P ONLY
SERVICING
54 GAS VALVE REPLACEMENT
SER
VICING
1.
Lift off front panel and
remove the grille assembly -
refer to Frames 28 & 29.
Undo the gas cock union.
Undo the 4 wing nuts and
remove the burner / controls
from the boiler.
2.
Remove the manifold from
the front plate.
3.
Unscrew the burner
injector(s) from the manifold.
4.
Fit the new injector(s), using
an approved jointing
compound, and re-assemble
in reverse order.
1.
Lift off front panel and remove the grille assembly - refer
Frames 28 & 29. Undo the gas cock union.
Undo the 4 wing nuts and remove the burner / controls from
the boiler.
2.
Undo the pilot supply connection.
3.
Undo the thermocouple connection.
4.
Unscrew the gas inlet pipe from the valve.
5.
Remove the 4 securing screws and withdraw the
valve from the burner manifold.
6.
Fit the new gas valve,
ensuring that:
a.
The valve is fitted the
correct way round -
an arrow engraved on
the valve indicates
the direction of flow.
b.
The sealing 'O' ring
supplied with the
valve is correctly
fitted at the outlet
flange.
c.
An approved jointing
compound is used
when reconnecting
the gas inlet pipe.
Summary of Contents for Mexico Super CF 3/60P