Mexico Super CF445 - CF475 - 

Users

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning of

this appliance care should be taken when handling edges of sheet steel components

Mexico Super

CF445

G.C. No. 41 392 81

Mexico Super

CF455

G.C. No. 41 392 82

Mexico Super

CF465

G.C. No. 41 392 83

Mexico Super

CF475

G.C. No. 41 392 84

MEXICO SUPER 

(

NATURAL GAS MODELS ONLY)

Certified - P.I. No. CF .................  87 AT 15

Destination Countries: GB, IE

INTRODUCTION

It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.

Current Gas Safety (Installation & Use)
Regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler
must be installed by a CORGI registered installer or in IE a
competent person, in accordance with the above regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz.

The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a plug
and socket, serving only the boiler and system controls. The
means of isolation must be accessible to the user after
installation.

Important Points

a.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

b.

The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.

c.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.

d.

Inflammable materials must not be placed in close proximity
to the appliance.  Materials giving off flammable vapours
must not be stored in the same room as the appliance.

e.

Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.

TTB Downdraught Thermostat
(CF boilers only)

This appliance is fitted with a TTB downdraught thermostat for
added safety and protection. If this thermostat should operate
and switch off the appliance it is because the flue is subject to
downdraught, probably as a result of adverse wind conditions.

The TTB is an automatic reset thermostat which will reset once
wind conditions have returned to normal, subject to a built-in
reset delay in excess of 10 minutes.

The TTB is an IMPORTANT SAFETY DEVICE and MUST NOT be
put out of action or interfered with in any way.

The TTB is not a substitute for an independently mounted
carbon monoxide detector.

In cases of repeated or continuous shutdown a CORGI
registered person or in IE a competent person should be called
to investigate and rectify the condition causing this and carry out
an operational test after each intervention on the device.  Only
the manufacturer's original parts should be used for
replacement.

Minimum Clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given in Table 1 MUST be complied
with, in order to maintain the safe running of the boiler.

200943-1.p65

3/4/2004, 1:58 PM

38

Summary of Contents for Mexico Super CF445

Page 1: ...ing instructions ENGINEERED FOR PEACE OF MIND When replacing a part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers CF445 CF455 CF465 CF475 200943 1 p65 3 4 2004 2 25 PM 37 ...

Page 2: ...iodically that the ventilation areas are free from any obstruction c If it is known or suspected that a fault exists on the boiler then it MUST NOT be used until the fault has been corrected by a CORGI registered installer or in IE a competent person d Inflammable materials must not be placed in close proximity to the appliance Materials giving off flammable vapours must not be stored in the same ...

Page 3: ...tem installed or as recommended by the installer To Shut Down the Boiler 1 For short periods Turn the boiler thermostat knob G to OFF When heating is again required restore the knob to its original setting 2 For longer periods a Turn the boiler thermostat knob G to OFF b Switch the electricity supply to OFF LEGEND A Gas control valve B Burner pressure test point C Main burner pressure adjuster D I...

Page 4: ...fter refilling contact the installer Has there previously been a smell of fumes from the flue It is likely that the downdraught thermostat has operated due to the combustion gases not being evacuated from the flue Contact your installer to check the flue is operating correctly and not blocked etc Boiler goes through ignition sequence but fails to light in either mode Check gas supply try at anothe...

Reviews: