23
SERVICING
Mexico Super CF445 - CF475 -
Installation & Servicing
31 BURNER AND CONTROLS ASSEMBLY REMOVAL
Check that:
a.
The pilot burner is clean and unobstructed.
b.
The ignition electrode is clean and undamaged.
c.
The ignition lead is in good condition and
securely connected.
d.
The spark gap is correct. Refer to Frame 44.
6.
Clean or renew components as necessary.
32 LINT GAUZE REMOVAL
33 CLEANING THE BURNER ASSEMBLY
1.
Clean the lint gauze to remove any deposits of lint, fluff etc.
2.
Brush off any deposits that may have fallen on to the burner
head, ensuring that the flame ports are unobstructed, and
remove any debris that may have collected.
Note.
Brushes with metallic bristles MUST NOT be used.
3.
Remove the main burner injector. Check, clean or replace,
as required.
4.
Refit the injector, using an approved jointing compound.
5.
Inspect the pilot burner and ignition electrode - ensure
that they are clear and in good condition.
MEX
2232
Gas service
union nut
Combustion
chamber
Wing nuts
MEX 2231
MEX 221
1
1.
Remove the 2 screws, lift off the front panel
and remove the grille assembly. Refer to
Frame 30.
2.
Disconnect the electrical leads from the gas
valve.
3.
Disconnect the ignition lead from the PCB.
4.
Undo the gas cock union. Remove the 4
wing nuts and withdraw the burner and
controls assembly, complete, from the
boiler.
5.
Remove the burner end cap.
6.
Withdraw the venturi baffle and lint gauze.
1.
Remove the 2 screws, lift off the front panel and
remove the grille assembly. Refer to Frame 30.
2.
Disconnect the electrical leads from the gas
valve.
3.
Disconnect the ignition
lead from the PCB.
4.
Undo the gas cock
union. Remove the 4
wing nuts and
withdraw the burner
and controls assembly,
complete, from the
boiler.
5.
Place on a convenient
working surface.
SER
VICING
200943-1.p65
3/4/2004, 1:58 PM
23