3
Mexico Super RS 3/40 - 3/80 -
Installation
Boiler Size
RS 3/40
RS 3/50
RS 3/60
RS 3/70
RS 3/80
Boiler Input
MINIMUM
kW (Btu/h)
11.3 ( 38 500)
15.1 (51 500)
18.5 (63 300)
22.2 (75 900)
26.2 (89 500)
Gas Consumption
l/s (ft.
3
/h)
0.29 (37.0)
0.39 (49.4)
0.48 (60.5)
0.57 (73)
0.68 (86)
MID
kW (Btu/h)
13.0 (44 200)
16.7 (56 800)
20.3 (69 200)
24.0 (81 900)
27.9 (95 200)
Gas Consumption
l/s (ft.
3
/h)
0.34 (42.6)
0.43 (54.7)
0.52 (65.8)
0.62 (79)
0.72 (92)
MAXIMUM
kW (Btu/h)
14.7 (50 300)
18.4 (62 600)
21.9 (74 800)
25.7 (87 700)
29.8 (101 700)
Gas Consumption
l/s (ft.
3
/h)
0.38 (48.1)
0.48 (60.2)
0.57 (71.7)
0.66 (84)
0.77 (98)
Boiler Output to Water
MINIMUM
kW (Btu/h)
8.8 (30 000)
11.7 (40 000)
14.7 (50 000)
17.6 (60 000)
20.5 (70 000)
MID
kW (Btu/h)
10.3 (35 000)
13.2 (45 000)
16.1 (55 000)
19.1 (65 000)
22.0 (75 000)
MAXIMUM
kW (Btu/h)
11.7 (40 000)
14.7 (50 000)
17.6 (60 000)
20.5 (70 000)
23.4 (80 000)
Burner Setting Pressure (hot)
MINIMUM
mbar (in w.g.)
6.2 (2.5)
8.4 (3.4)
9.5 (3.8)
8.8 (3.5)
11.2 (4.5)
MID
mbar (in w.g.)
8.0 (3.2)
10.4 (4.2)
11.3 (4.5)
10.3 (4.1)
12.6 (5.0)
MAXIMUM
mbar (in w.g.)
10.6 (4.2)
12.7 (5.1)
13.1 (5.2)
11.9 (4.8)
14.2 (5.7)
Flue Gas Flow Rate
g/s
6.9
8.6
10.3
12.1
14.0
Flue Gas Temperature
O
C
138
142
129
118
173
*
Seasonal Efficiency
(SEDBUK) %
72.7
71.7
73.6
72.5
72.1
Boiler Size
RS 3/40
RS 3/50
RS 3/60
RS 3/70
RS 3/80
Gas Supply Connection
in. BSP
Rc 1/2 (1/2)
Number of Boiler Sections
2
3
3
3
3
Flow and Return Connections
Rc 1 (1" BSP)
MAXIMUM Static Water Head
m (ft.)
30.5 (100)
(3 bar)
MINIMUM Static Water Head
m (ft.)
1.0 (3.3)
Electrical Supply
230 V ~50 Hz
External Fuse Rating(Power Consumption)
3 A
(5 W)
Water Content
litre (gal.)
5.0 (1.1)
7.4 (1.6)
Dry Weight
kg. (lb.)
68 (150)
90 (198)
Boiler Size
Height
mm (in.)
850 (33.5)
Width
mm (in.)
440. (17.4)
Depth
mm (in.)
533 (21.0)
Gas Type
Natural 2 H
Gas Supply Pressure
20 mb
GENERAL
Table 1 - General Data
Table 2 - Performance Data
Key to symbols
IE
= Ireland
GB
= United Kingdom (Countries of destination)
PMS
= Maximum operating pressure of water
C
11
= A room sealed appliance designed for connection via
ducts to a horizontal terminal, which admits fresh air
to the burner and discharges the products of
combustion to the outside without a fan in the
combustion products circuit.
I
2H
= An appliance designed for use on 2nd Family gas,
Group H only.
Note.
Gas consumption is calculated using a calorific value of 38.7
MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett.
To obtain the gas consumption at a different calorific value:-
a.
For l/s - divide the gross heat input (kW) by the gross
C.V. of the gas (MJ/m
3
)
b.
For ft
3
/h - divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
c.
The appliance is pre-set at the factory to the highest
nominal rating.
*
The value is used in the UK government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by BGplc 0087.