Mexico Super RS440 - RS470 -
Installation & Servicing
GENERAL
2 FLOOR MOUNTING AND BOILER CLEARANCES
Flammable materials must not be placed in close proximity
to the appliance. Materials giving off flammable vapours
must not be stored in the same room as the appliance.
Floor mounting
1.
The floor must be flat, level and of suitable load bearing
capacity.
2.
The back of the boiler may be fitted up to the wall.
Boiler clearances
The minimum overall dimensions of the space in which the
boiler is to operate and to facilitate servicing are as follows:-
Additional space will be required for installation, depending
upon site conditions.
IMPORTANT.
In order to facilitate gas connection, a clearance of at least
100 mm (4") must be available at either the LH side or the
RH side DURING installation. Refer to Frame 14.
In addition a MINIMUM clearance of 533 mm (21") MUST be
available at the front of the boiler, for servicing.
Terminal sizes
Boiler Size
Depth
Height
Width
RS440, RS450,
152
338
372
RS460 & RS470
Boiler Size
Width
Depth
Height
RS440, RS450,
460 mm 533 mm
870 mm
RS460 & RS470.
(18")
(21")
(34
1/4"
)
1 BOILER WATER CONNECTIONS
1.
This appliance is NOT suitable for use in
a direct hot water system.
2.
If the boiler is to be used on a sealed
system, an Overheat Thermostat Kit is
available and must be installed in
accordance with the instructions
supplied with the kit.
Boiler
Dimension A
RS440
152mm (6")
RS450, RS460
226mm (8
7/8
")
RS470