FAULT FINDING
mini HE
--- Installation & Servicing
53
Continued from
page 51 of fault
finding
Repair or replace
faulty flame detection
signal connection
harness. Refer to
frame 41.
yes
yes
yes
yes
no
no
no
no
no
no
no
no
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
Is dip---switch # 3 in
the off position?
Refer to frame 27.
Is dip---switch # 3 in
the off position?
Refer to frame 27.
Is LED 1 on and LED
2 flashing?
Replace faulty PCB #1
Switch to on position.
Is the fan running?
Is there 230V at the
fan connections?
Are the sensing pipes
undamaged and
connected?
Replace faulty PCB #1
Is LED 1 flashing and
LED 2 and LED 3 on?
Switch to on position.
Is there 230V at
pin 101 PCB # 2?
Repair or replace
faulty wiring.
Is there continuity of
the Air Pressure
Switch harness?
Is there continuity
between NC and C at
the Air Pressure
Switch?
Replace faulty fan.
Replace faulty Air
Pressure Switch.
Is there continuity
across C and NO on
the Air Pressure
Switch?
Repair or replace
wiring.
Are the connections
between PCB # 1 and
PCB # 2 O.K?
Clear flue
Repair or replace
Is the burner on?
Is the flue clear and
venturi O.K?
Replace sensing
pipes.
Replace faulty PCB #2
Replace faulty PCB #1
Repair or replace
faulty wiring.
Is the Air Pressure
Switch harness
continuity O.K?
Replace faulty Air
Pressure Switch
Replace faulty PCB #2
FA
U
LT
F
IN
D
IN
G