Boiler opentherm wiring - Logic

Boiler opentherm wiring - Vogue

Remove boiler front panel by 
removing two screws.

Loosen the two screws on 
the front panel and release 
catches at rear.  Remove the 
front panel

Hinge down the control panel.

Release the edge clips to 
hinge open the cover.

Hinge down the control panel.

Remove screw and release 
the clip.

Connect two wires from the boiler opentherm terminal strip to the opentherm 
connections in the relay transceiver.
Maintain 10mm separation between the mains cable and the opentherm cables.
Replace the PCB cover and boiler front panel.  
Replace transceiver cover.
Do not switch power on.

Connect two wires from the boiler opentherm terminal strip to the opentherm 
connections in the relay transceiver.
Maintain 10mm separation between the mains cable and the opentherm cables.
Replace the PCB cover and boiler front panel.  
Replace transceiver cover.
Do not switch power on.

2

2

1

1

3

3

WEATHER

COMPENSATION

OPENTHERM

Boiler control box

Relay transceiver

+ / - not relevant

here as opentherm

connection is not

polarity specific

WEATHER

COMPENSATION

OPENTHERM

Boiler control box

Relay transceiver

+ / - not relevant

here as opentherm

connection is not

polarity specific

Summary of Contents for touch

Page 1: ...Installation guide Wireless room thermostat with hot water control DHW single zone CH Logic Heat H Logic Max Heat H Logic System S Logic Max System S Vogue System Vogue Max System ...

Page 2: ...icity supply to the appliance and heating system before installing the transceiver Merely switching the boiler to OFF will still leave a live feed to the boiler Notes on opentherm wiring The opentherm wire must be connected from the relay transceiver to the boiler A separation of 10mm must be achieved between the opentherm wiring and 230V wiring Use 0 5mmsq heat resistant flex For routing of cable...

Page 3: ...l br g y gr or w KEY blue brown green yellow grey orange white Cylinder Stat 1 C 2 Y plan valve or bl g y w gr Pump if external to boiler WEATHER COMPENSATION OPENTHERM Opentherm Pump if external to boiler Relay Transceiver 1 2 3 4 5 6 7 8 9 10 R S Room Stat HW Hot Water C S Cylinder Stat Cylinder Stat 1 C DHW valve CH valve g y bl gr or or br bl gr g y br wiring centre not supplied bl br g y gr o...

Page 4: ... mains cable and the opentherm cables Replace the PCB cover and boiler front panel Replace transceiver cover Do not switch power on Connect two wires from the boiler opentherm terminal strip to the opentherm connections in the relay transceiver Maintain 10mm separation between the mains cable and the opentherm cables Replace the PCB cover and boiler front panel Replace transceiver cover Do not swi...

Page 5: ...d not be placed near draughts in direct sunlight or near heat sources Thermostat installation Off On Auto MON 10 20 ZONE 1 20 5 Set system date DONE BACK 01 01 18 20 5 CONNECTING TO BOILER 20 5 Set system time DONE 00 00 Wait for the screen shown on the left to be displayed In the unlikely event that this screen is not shown within 20 seconds electrically isolate the boiler and heating system remo...

Page 6: ...Battery replacement Batteries should operate for approximately 18 to 24 months Only good quality alkaline batteries are to be used If the batteries run out then central heating and hot water will continue to operate during the set time periods but room temperature control will become less accurate Un clip the thermostat from its cradle by sliding the Touch thermostat upwards Using a flat bladed sc...

Page 7: ...n onto the boiler PCB are securely connected Check that there is 230V to the zone valve from relay transceiver R S On connection If no response to previous actions isolate power to boiler and heating system and return to step 1 page 8 Central Heating will not switch OFF Check that central heating is set to OFF or is in a programmed Off period and that the override is off If is shown on the room th...

Page 8: ... the controls To any defect resulting from the incorrect installation of the controls To any costs incurred during delays in fixing reported faults Our Ideal Warranty is offered in addition to the rights provided to a consumer by law Details of these rights can be obtained from a Trading Standards Authority or a Citizens Advice Bureau Guarantor Ideal Boilers Ltd P O Box 103 National Avenue Hull HU...

Page 9: ... Technical Helpline T 01482 498663 SCAN HERE FOR FURTHER HELP For further information including a User Guide and FAQs see www idealboilers com Ideal Boilers Ltd P O Box 103 National Avenue Hull HU5 4JN www idealboilers com 212878 A02 ...