Using a flat bladed 
screwdriver remove the 
back cover from the 
Touch thermostat and 
insert only 3 batteries.

Immediately insert the 
fourth battery into  
the thermostat. 

Turn electrical power 
back on to the boiler and 
heating system.

2M

Off

On

Auto

MON 10:20

ZONE 1

Hold the thermostat 
approx 2 metres 
away from the relay 
transceiver.

1

2

3

4

Thermostat location guidelines

In-between the Ideal relay transceiver and the Touch thermostat there must be:

• Less than 20 metres
• No more than a total of 3 walls and ceilings
• No large metallic objects (e.g. American fridge/freezer)
• No large mirrors or windows
• No walls running along the RF path

The Touch thermostat must not be within 1 metre of a wifi booster / router and 
should not be placed near draughts, in direct sunlight or near heat sources. 

Thermostat installation

Off

On

Auto

MON 10:20

ZONE 1

20.5

Set system date

DONE

BACK

01  01  18

20.5

CONNECTING TO

BOILER

20.5

Set system time

DONE

00  00

Wait for the screen shown on the 
left to be displayed. (In the unlikely 
event that this screen is not shown 
within 20 seconds, electrically 
isolate the boiler and heating 
system, remove one battery and 
repeat from step 2.)

When successfully connected the 
screen shown on the left will be 
displayed. Set the 24hr clock, then 
select “DONE”. 

Set  the  date,  then  select  “DONE”.          
If the screen goes blank before 
set up is complete, tap the screen 
and select MENU to access Help & 
Settings to set time and date.  

When set up is complete the screen 
will go blank.

5

6

7

8

Installation 

To attach the thermostat to the wall bracket or desktop stand locate the thermostat 
into the 3 lugs and slide downwards until it clicks.

Transceiver

Summary of Contents for touch

Page 1: ...Installation guide Wireless room thermostat with hot water control DHW single zone CH Logic Heat H Logic Max Heat H Logic System S Logic Max System S Vogue System Vogue Max System ...

Page 2: ...icity supply to the appliance and heating system before installing the transceiver Merely switching the boiler to OFF will still leave a live feed to the boiler Notes on opentherm wiring The opentherm wire must be connected from the relay transceiver to the boiler A separation of 10mm must be achieved between the opentherm wiring and 230V wiring Use 0 5mmsq heat resistant flex For routing of cable...

Page 3: ...l br g y gr or w KEY blue brown green yellow grey orange white Cylinder Stat 1 C 2 Y plan valve or bl g y w gr Pump if external to boiler WEATHER COMPENSATION OPENTHERM Opentherm Pump if external to boiler Relay Transceiver 1 2 3 4 5 6 7 8 9 10 R S Room Stat HW Hot Water C S Cylinder Stat Cylinder Stat 1 C DHW valve CH valve g y bl gr or or br bl gr g y br wiring centre not supplied bl br g y gr o...

Page 4: ... mains cable and the opentherm cables Replace the PCB cover and boiler front panel Replace transceiver cover Do not switch power on Connect two wires from the boiler opentherm terminal strip to the opentherm connections in the relay transceiver Maintain 10mm separation between the mains cable and the opentherm cables Replace the PCB cover and boiler front panel Replace transceiver cover Do not swi...

Page 5: ...d not be placed near draughts in direct sunlight or near heat sources Thermostat installation Off On Auto MON 10 20 ZONE 1 20 5 Set system date DONE BACK 01 01 18 20 5 CONNECTING TO BOILER 20 5 Set system time DONE 00 00 Wait for the screen shown on the left to be displayed In the unlikely event that this screen is not shown within 20 seconds electrically isolate the boiler and heating system remo...

Page 6: ...Battery replacement Batteries should operate for approximately 18 to 24 months Only good quality alkaline batteries are to be used If the batteries run out then central heating and hot water will continue to operate during the set time periods but room temperature control will become less accurate Un clip the thermostat from its cradle by sliding the Touch thermostat upwards Using a flat bladed sc...

Page 7: ...n onto the boiler PCB are securely connected Check that there is 230V to the zone valve from relay transceiver R S On connection If no response to previous actions isolate power to boiler and heating system and return to step 1 page 8 Central Heating will not switch OFF Check that central heating is set to OFF or is in a programmed Off period and that the override is off If is shown on the room th...

Page 8: ... the controls To any defect resulting from the incorrect installation of the controls To any costs incurred during delays in fixing reported faults Our Ideal Warranty is offered in addition to the rights provided to a consumer by law Details of these rights can be obtained from a Trading Standards Authority or a Citizens Advice Bureau Guarantor Ideal Boilers Ltd P O Box 103 National Avenue Hull HU...

Page 9: ... Technical Helpline T 01482 498663 SCAN HERE FOR FURTHER HELP For further information including a User Guide and FAQs see www idealboilers com Ideal Boilers Ltd P O Box 103 National Avenue Hull HU5 4JN www idealboilers com 212878 A02 ...