Warranty

All Ideal Touch Controls offer customers the comfort of a 12 month Ideal warranty, 
subject to the following terms and conditions. During the period of the warranty we 
will replace free of charge, where it suffers a mechanical or an electrical breakdown 
as a result of defective workmanship or materials, subject to the following conditions 
and exclusions;

The warranty will commence from the 
date of installation. Without proof of 
purchase the warranty will commence 
from the date of manufacture (via 
serial number). 

The Installation needs to be registered 
within 30 days of installation, it can be 
registered online by visiting  

www.idealboilers.com

If the control suffers a mechanical or 
an electrical breakdown we should be 
contacted on one of the  
following numbers:

Northern Ireland: 02890 331444 
Elsewhere in the UK: 01482 498660 
Our normal working times, excluding 
Bank holidays, are:
8am – 6pm Monday to Friday
8am – 4pm Saturday
8am – 12 noon Sunday

The warranty does not apply:

To any defect, damage or breakdown 
caused by deliberate action, accident, 
misuse or third party interference 
including modification or  
failed batteries.

To any defect, damage or breakdown 
caused by the design, installation  
and maintenance of the central  
heating system.

To any other costs or expenses 
caused by or arising as a result of the 
breakdown of the controls.

To any defect resulting from the 
incorrect installation of the controls. 
To any costs incurred during delays in 
fixing reported faults.

Our Ideal Warranty is offered in 
addition to the rights provided to 
a consumer by law. Details of these 
rights can be obtained from a Trading 
Standards Authority or a Citizens 
Advice Bureau. 

Guarantor – Ideal Boilers Ltd, P.O. Box 
103, National Avenue, Hull, HU5 4JN.

FAULT

ACTION

Hot Water will 

not switch ON

Check that hot water is set to be 

 ON or is in a programmed 

on period or the override 

 is on.

Check that the cylinder thermostat is calling for heat (230V to C/S 
on connection on relay transceiver).

Check that the power to the boiler is switched on.
For Logic boilers ensure that the mode knob is on.

For Vogue system boilers ensure that the 

 knobs are not 

rotated fully anti-clockwise.

Check that the 

 light on the relay transceiver is on, if not then 

check there is mains supply to the relay transceiver.

If the relay transceiver 

 light is off then check if the wires from 

the relay transceiver to the boiler and then onto the boiler PCB are 
securely connected.

Check that there is 230V to the zone valve (from relay transceiver 
hot water on connection).

If no response, to previous actions, isolate power to boiler and 
heating system and return to step 1 page 8.

Hot Water will 
not switch OFF

Check that hot water is set to 

 OFF or is in a programmed off 

period and that the Override 

 is off.

If no response, to previous actions, isolate power to boiler and 
heating system and return to step 1 page 8.

Summary of Contents for touch

Page 1: ...Installation guide Wireless room thermostat with hot water control DHW single zone CH Logic Heat H Logic Max Heat H Logic System S Logic Max System S Vogue System Vogue Max System ...

Page 2: ...icity supply to the appliance and heating system before installing the transceiver Merely switching the boiler to OFF will still leave a live feed to the boiler Notes on opentherm wiring The opentherm wire must be connected from the relay transceiver to the boiler A separation of 10mm must be achieved between the opentherm wiring and 230V wiring Use 0 5mmsq heat resistant flex For routing of cable...

Page 3: ...l br g y gr or w KEY blue brown green yellow grey orange white Cylinder Stat 1 C 2 Y plan valve or bl g y w gr Pump if external to boiler WEATHER COMPENSATION OPENTHERM Opentherm Pump if external to boiler Relay Transceiver 1 2 3 4 5 6 7 8 9 10 R S Room Stat HW Hot Water C S Cylinder Stat Cylinder Stat 1 C DHW valve CH valve g y bl gr or or br bl gr g y br wiring centre not supplied bl br g y gr o...

Page 4: ... mains cable and the opentherm cables Replace the PCB cover and boiler front panel Replace transceiver cover Do not switch power on Connect two wires from the boiler opentherm terminal strip to the opentherm connections in the relay transceiver Maintain 10mm separation between the mains cable and the opentherm cables Replace the PCB cover and boiler front panel Replace transceiver cover Do not swi...

Page 5: ...d not be placed near draughts in direct sunlight or near heat sources Thermostat installation Off On Auto MON 10 20 ZONE 1 20 5 Set system date DONE BACK 01 01 18 20 5 CONNECTING TO BOILER 20 5 Set system time DONE 00 00 Wait for the screen shown on the left to be displayed In the unlikely event that this screen is not shown within 20 seconds electrically isolate the boiler and heating system remo...

Page 6: ...Battery replacement Batteries should operate for approximately 18 to 24 months Only good quality alkaline batteries are to be used If the batteries run out then central heating and hot water will continue to operate during the set time periods but room temperature control will become less accurate Un clip the thermostat from its cradle by sliding the Touch thermostat upwards Using a flat bladed sc...

Page 7: ...n onto the boiler PCB are securely connected Check that there is 230V to the zone valve from relay transceiver R S On connection If no response to previous actions isolate power to boiler and heating system and return to step 1 page 8 Central Heating will not switch OFF Check that central heating is set to OFF or is in a programmed Off period and that the override is off If is shown on the room th...

Page 8: ... the controls To any defect resulting from the incorrect installation of the controls To any costs incurred during delays in fixing reported faults Our Ideal Warranty is offered in addition to the rights provided to a consumer by law Details of these rights can be obtained from a Trading Standards Authority or a Citizens Advice Bureau Guarantor Ideal Boilers Ltd P O Box 103 National Avenue Hull HU...

Page 9: ... Technical Helpline T 01482 498663 SCAN HERE FOR FURTHER HELP For further information including a User Guide and FAQs see www idealboilers com Ideal Boilers Ltd P O Box 103 National Avenue Hull HU5 4JN www idealboilers com 212878 A02 ...