33
Installation and Servicing
SECTION 2 - INSTALLATION
Ideal offers the following kits:-
(see individual kits for installation instructions)
Mechanical Timer (24 hr)
: 24 hour mechanical CH timer fits into the control box of the boiler. This can be fitted in conjunction
with a Room Thermostat.
RF Electronic 7 Day Programmable Room Thermostat
: Transceivers fit into boiler. Room thermostat can be located as
desired.
Weather Compensation Kit:
allows outside temperature sensing.
Ideal Touch Combi RF Programmable Room Thermostat:
Transceivers fit into boiler. Portable room thermostat.
2.18 OPTIONAL SYSTEM CONTROLS KITS
The Vogue Max Combi boiler comes pre-fitted with a link wire between the Room Thermostat/Timer connections on the terminal
strip. This creates a permanent call for heat and must be removed when adding a Room Thermostat/Timer.
2.19 INTERNAL WIRING - EXTERNAL CONTROLS
To add wired external Room Thermostats, Timers or
Programmers proceed as follows:-
1. Isolate the mains supply to the boiler.
2. Remove the front panel (refer to Section 3.2).
3. Swing the control box down into the servicing position
(refer to Section 3.3).
4. Route incoming cables through the grommets in the
bottom panel (note: grommets are ‘blind’ and will require
puncturing) and secure using clamps and screws provided
in the hardware pack.
5. Remove the installer wiring cover.
6. Connect wires to the plugs which may be removed to aid
wiring.
7. Re-assemble in reverse order.