3.19 DIVERTER VALVE ACTUATOR REPLACEMENT
1. Set the Diverter Valve to mid
position, using the boiler controls.
Refer to page 46 (3 WAY VALVE
MIDPOSITION).
2. Refer to Sections 3.2 & 3.3.
3. Disconnect the electrical cable
connection on the diverter valve
actuator.
4.
Place a flat bladed screwdriver in the
actuator slot provided and ease out the
actuator.
5. Lift the valve actuator clear of the valve
body.
6. Fit the new motor ensuring the arm is
correctly engaged in the metal fork and
re-assemble in reverse order.
7. Check the operation of the boiler.
Refer to Sections 2.24 to 2.27.
3.20 CONDENSATE TRAP REPLACEMENT
1. Refer to Sections 3.2 & 3.3.
2. Remove the rubber condensate pipe from
the top of the trap.
3. Rotate the trap clockwise to disengage
the trap and lift clear of the outlet
connection.
4.
Replace the trap and refit in reverse order
making sure the trap is engaged with the
outlet connection.
5.
Refill the condensate trap.
6. Check the operation of the boiler. Refer to
Sections 2.24 to 2.27.