The wall mounting template is located on the internal
protective packaging.
Note.
The template shows the positions of the fixing holes
and the position of the air and flue connections. Care MUST
be taken to ensure the correct holes are drilled.
1. Tape template into the selected position. Ensure
squareness by hanging a plumbline as shown.
2. Mark onto the wall the following:
a The wall mounting plate screw positions (choose one
from each group).
b The position of the air and flue when exiting straight out
of the wall where the boiler is mounted.
Note.
Mark the centre of the hole as well as the
circumference.
3. Remove the template from the wall.
2.3 WALL MOUNTING TEMPLATE
2.4 PREPARING THE WALL
WARNING
Ensure that, during the cutting operation,
masonry falling outside of the building does not cause
damage or personal injury.
1. Cut the flue and air holes (preferably with 60mm core bore
tool) ensuring the holes are square to the wall.
2. Drill 2 holes with a 7.5mm / 8mm masonry drill and insert
the plastic plugs, provided, for the wall mounting plate.
3. Locate 2 No.14 x 50mm screws in the wall mounting plate
(one at each side, in any of the 3 holes provided at each
side) and screw home.
2.5 FITTING THE WALL MOUNTING PLATE
1. Lift the boiler onto the wall mounting plate and locate it
over the 2 tabs.
2.6 MOUNTING THE BOILER
1. Screw the wall mounting plate to the wall using 2 wall
plugs fitted previously with the 2 screws provided.
2. Choose one of the 2 sets of slots in left and right bank.
Ensure that at least one of the screws is fitted into a top
slot and the mounting bracket is level.
esp9496
Example of fixing
3G10030
X
Section
through wall
Note.
Check all of the hole
positions before drilling.
Rear flue only
60mm diameter
holes
IMPORTANT:
Ensure the wall
where the boiler
will be is flat.
16
Installation and Servicing
Section 2 - Installation
INST
ALLA
TION