Table 1 General Data
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett.
To obtain the gas consumption at a different calorific value:
a. For l/s - divide the gross heat input (kW) by the gross C.V. of
the gas (MJ/m
3
)
b. For Btu/h - multiply the gross heat input (kW) by 26.8
c. For ft
3
/h - divide the gross heat input (Btu/h) by the gross C.V.
of the gas (Btu/ft
3
)
d. For m
3
/h - multiply l/s by 3.6
C13 C33 C53
= A room sealed appliance designed for connection via
ducts to a horizontal or vertical terminal, which admits
fresh air to the burner and discharges the products of
combustion to the outside through orifices which, in
this case, are concentric. The fan is up stream of the
combustion chamber.
I
2H
= An appliance designed for use on 2nd family gas, Group H
only.
II
2H/3P
= An appliance designed for use on 2nd or 3rd family gases,
Group H or P.
* The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data from which
it has been calculated, has been certified by a notified body.
** The value is used in the Irish Government’s Dwelling Energy Assessment
Procedure (DEAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
*Required for maximum flow rate. Boiler operates down to 2 L/min DHW delivery ** In areas of low water pressure the DHW restrictor can be removed
30 kW
35 kW
Gas Supply
2H - G20 - 20 mbar
Gas Supply Connection
15 mm copper compression
Injector Size
mm
4.65
4.9
Inlet Connection
Cold Water
15 mm copper compression
Outlet Connection
Cold Hot Water
15 mm copper compression
Flow Connection
Central Heating
22 mm copper compression
Return Connection
Central Heating
22 mm copper compression
Flue Terminal Diameter
mm
50
Average Flue Temp-Mass Flow Rate
DHW
68ºC - 13g/s
73ºC - 15g/s
CO2 Content (± 0.7)
Max. DHW
9.3%
9.7%
Min. CH
8.5%
8.8%
Maximum Working Pressure (Sealed Systems)
bar (psi)
2.5 (36.3)
Maximum Domestic Hot Water Inlet Pressure
bar (psi) [kPa]
10.0(145)
[1000]
Minimum Domestic Hot Water Inlet Pressure*
bar (psi) [kPa]
1.3(18.9) [130]
1.3(18.9)**[130]
Minimum DHW Inlet Pressure to Operate at 0.6 bar System
Pressure
All Model Sizes 0.5 bar
Electrical Supply
230 V ~ 50 Hz
Power Consumption
W
93
110
Fuse Rating
External : 3 A Internal : T4A HRC L250 V
Water Content
Central Heating litre (gal)
1.2 (0.26)
Domestic Hot Water litre (gal)
1.0 (0.22)
Packaged Weight
kg
32.9
32.9
Lift Weight
kg
28.6
28.6
Boiler Casing Size
Height mm
700
Width mm
395
Depth mm
278
Boiler Input:
Max
Min
30 kW
35 kW
kW
24.3
6.1
7.1
Gross CV
kW
27
6.7
7.9
Gas Consumption
m3/h
2.512
0.627
0.734
(ft
3
/h)
(89)
(22)
(25.9)
Boiler Output :
Non Condensing
70ºC Mean Water Temp.
kW
24.2
6.1
7.1
Condensing
40ºC Mean Water Temp.
kW
25.6
6.4
7.5
Seasonal Efficiency* SEDBUK 2005
91.10%
91.10%
Seasonal Efficiency* SEDBUK 2009/2012
89.60%
89.60%
SEAI HARP*
91.10%
91.10%
NOx Classification
CLASS 6
Maximum DHW Input:
30 kW
35 kW
Nett CV
kW
30.4
35.4
Gross CV
kW
33.7
39.3
Gas Consumption
m
3
/h
3.135
3.657
ft
3
/h
111
129
Maximum DHW Output
kW
30.3
35.3
DHW Flow Rate
l/min
12.4
14.5
At 35ºC Temp. Rise
gpm
2.8
3.2
DHW Specific Rate
l/min
14.5
16.9
gpm
3.2
3.7
6
Installation and Servicing
Section 1 - General
Table 2 Performance Data - Central Heating
Table 3 Performance Data - Domestic Hot Water