39
Installation and Servicing
SECTION 2 - INSTALLATION
INST
ALLA
TION
MIN
MAX
MIN
MODE
e
BOILER
OFF
MAX
2.28 RESTART PROCEDURE
6.
Explain and demonstrate the function of timers and
temperature controls, radiator valves etc., for the economic
use of the system.
7.
If a timer is fitted draw attention to the timer Users
Instructions and hand them to the householder.
8.
Loss of system water pressure
Explain that the dial on the control panel front indicates
the central heating system pressure and that if the normal
COLD pressure of the system is seen to decrease over a
period of time then a water leak is indicated. Explain the re-
pressurising procedure and if unable to re-pressurise or if the
pressure continues to drop a registered local heating installer
should be consulted. Refer to Section 2.19.
9.
Explain boiler restart procedure. Refer to Section 2.28.
10.
After installation and commissioning please complete the
Commissioning Checklist before handover to the customer.
IMPORTANT
11.
A comprehensive service should be carried out ANNUALLY.
Stress the importance of regular servicing by a Licensed &
Registered Engineer.
12.
Inform the householder of the guarantee/registration found
within the envelope pack and the requirement to register it to
receive the full benefit of the warranty.
1.
Hand the User Instructions to the householder and
explain his/her responsibilities under the relevant national
regulations.
2.
Explain and demonstrate the lighting and shutting down
procedures.
3.
The operation of the boiler and the use and adjustment of all
system controls should be fully explained to the householder,
to ensure the greatest possible fuel economy consistent with
the household requirements of both heating and hot water
consumption.
Advise the User of the precautions necessary to prevent
damage to the system and to the building, in the event of the
system remaining inoperative during frosty conditions.
4.
Explain the function and the use of the boiler heating and
domestic hot water controls.
Explain that due to system variations and seasonal
temperature fluctuations DHW flow rates/temperature
rise will vary, requiring adjustment at the draw off tap. It
is therefore necessary to draw the user’s attention to the
section in the Users Instructions titled “Control of Water
Temperature” and the following statement:
“Additionally, the temperature can be controlled by the
user via the draw-off tap: the lower the rate the higher
the temperature, and vice versa”
.
5.
Explain the function of the boiler fault mode.
After completing the installation and commissioning of the system the installer should hand over to the householder by
the following actions:
2.29 HANDING OVER
To restart the boiler, press the RESTART button (F).
Legend
A. Domestic Hot Water Temperature Knob
B. Central Heating Temperature Knob
C. Mode Knob
D. Boiler status Display
E. Burner ‘on’ Indicator
F. Restart Button
G. Preheat On/Off Button
H. Pressure Gauge
A
D
E
B
C
G
F
H