background image

CONTENTS

 

1.1 Introduction 

 ................................................................................3

1.2  Boiler Operation .......................................................................4-5
1.3  System Water Pressure ..............................................................6
1.4  Points for the boiler user .............................................................6
1.5  Frozen Condensate Drain ...........................................................7
1.6  General Information.....................................................................7
1.7 Troubleshooting ...........................................................................8
1.8  Display Functions - Normal Operation Mode ..............................9
1.9  Display Functions - Fault messages .........................................10

1.1  INTRODUCTION

The Logic MAX Combi

2

 

is a combination boiler providing 

both central heating and instantaneous domestic hot water.  

Featuring full sequence automatic ignition and fan assisted 

combustion.

Due to the high efficiency of the boiler, condensate is produced 

from the flue gases and this is drained to a suitable disposal 

point through a plastic waste pipe at the base of the boiler.  A 

condensate ‘plume’ will also be visible at the flue terminal.

Safety

Current Gas Safety (Installation & Use) Regulations 

or rules in force.

It is the law that this appliance installation and any work carried 

out on the appliance is carried out by a  Gas Safe Registered 

engineer in accordance with the above Regulations.
It is essential that the instructions in this booklet are strictly 

followed, for safe and economical operation of the boiler.

Electricity Supply

This appliance must be earthed.

Supply: 230 V ~ 50 Hz. The fusing should be 3 A.

Important Notes

•  This appliance must not be operated without the casing 

correctly fitted and forming an adequate seal.

•  If the boiler is installed in a compartment then the 

compartment MUST NOT be used for storage purposes.

•  If it is known or suspected that a fault exists on the boiler 

then it MUST NOT BE USED until the fault has been 

corrected by a Gas Safe Registered Engineer.

 

Under NO circumstances should any of the sealed 

components on this appliance be used incorrectly or 

tampered with.

•  T

his appliance can be used by children 8 

years and above.  

A

lso persons with reduced 

physical, sensory or mental capabilities, or 

lack of experience and knowledge, provided 

they have been given supervision or 

instruction concerning use of the appliance 

in a safe way and understand the hazards 

involved.  Children shall not play with the 

appliance.  

C

leaning and user maintenance 

shall not be made by children without 

supervision.

3

User Guide

 

USER

Summary of Contents for LOGIC MAX COMBI 2 C24

Page 1: ...equire Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our websit...

Page 2: ...s been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety...

Page 3: ...bove Regulations It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler Electricity Supply This appliance must be earthed Supply 23...

Page 4: ...reheat On Summer Conditions Domestic Hot Water only required Press the Mode button until Ready or On is shown under the Tap symbol and Off is shown under the Radiator symbol OR Set the central heating...

Page 5: ...perature Turn the knob clockwise to increase room temperature and anti clockwise to decrease room temperature Once the desired setting has been achieved leave the knob in this position and the system...

Page 6: ...n gradually turn the filling loop handle green B to the horizontal position 6 Wait for the pressure gauge to reach 1 to 1 5 bar 7 Once pressure is reached turn valves B back to the closed position 8 D...

Page 7: ...ng warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Start the boiler 5 If the applian...

Page 8: ...in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the mains power is turned on and that the tap and radiator symbols are either blue or orange See boiler Di...

Page 9: ...0 C Set by Room Stat Ready Winter Mode Pre heat Demand Switch Off at 60 C Preheat Menu Mode Ready On Radiator Target 60 C Room Thermostat or Timer Off Preheat Active Summer Mode No Heat Demand Target...

Page 10: ...staller Restart Menu Return Thermistor Fault Contact Installer Menu Fan Fault Contact Installer Menu PCB Fault Contact electricity provider Menu Low Mains Voltage 1 With boiler off system cold fill sy...

Page 11: ...Thermistor Fault Contact electricity provider Restart Menu Gas Valve Fault 1 Check if condensate pipe blocked frozen 2 Check if flue blocked 3 If fault persists contact installer Restart Menu Blocked...

Page 12: ...eal Technical Helpline 01482 498663 Ideal Consumer Helpline 01482 498660 Ideal Parts 01482 498665 idealheating com Ideal Boilers Ltd pursues a policy of continuing improvement in the design and perfor...