User Guide

  

5

USER

1.5  LOSS OF SYSTEM WATER PRESSURE

The gauge (G) indicates the central heating system pressure. 
If the pressure is seen to fall below the original installation 
pressure of 1-2 bar over a period of time then a water leak 
may be indicated. In this event conduct the re-pressurising 

procedure as follows:
Re-pressurise via the filling loop to 1 bar (if unsure contact 

your installer). Turn off the tap on the filling loop and press the 

“RESTART” button (E) to restart the boiler.

If unable to do so or if the pressure continues to drop after 

filling a Gas Safe Registered Engineer should be consulted.

Note.

  The boiler will not operate if pressure has reduced to 

less than 0.3 bar under this condition.

FOR ANY QUERIES PLEASE RING THE IDEAL 

CONSUMER HELPLINE : 01482 498660

BOILER RESTART PROCEDURE -  To restart boiler 

press the restart button (E)

1.6  POINTS FOR THE BOILER USER

 In line with our current warranty policy we would ask that you 
check through the following guide to identify any problems 
external to the boiler prior to requesting a service engineers 
visit.  Should the problem be found to be other than with the 
appliance we reserve the right to levy a charge for the visit, or 
for any pre-arranged visit where access is not gained by the 
engineer.

Preventative solutions

During cold weather, set the central heating temperature knob 
(A) to maximum (must return to original setting once cold spell 
is over).

Place the heating on continuous and turn the room thermostat 
down to 15ºC overnight or when unoccupied. (Return to normal 
after cold spell).

1.4  GENERAL INFORMATION

BOILER PUMP

The boiler pump will operate briefly as a self-check once every 

24 hours, regardless of system demand.

MINIMUM CLEARANCES

Clearance of 165mm above, 100mm below, 2.5mm at the sides 
and 450mm at the front of the boiler casing must be allowed for 
servicing.

Bottom Clearance

Bottom clearance after installation can be reduced to 5mm.

This must be obtained with an easily removable panel, to 
enable the system pressure gauge to be visible and to provide 
the 100mm clearance required for servicing.

ESCAPE OF GAS

Should a gas leak or fault be suspected contact the National 
Gas Emergency Service without delay.

Telephone 0800 111 999

.    

Ensure that;

-  All naked flames are extinguished

-  Do not operate electrical switches

-  Open all windows and doors

CLEANING

For normal cleaning simply dust with a dry cloth.  To remove 

stubborn marks and stains, wipe with a damp cloth and finish off 

with a dry cloth.  

DO NOT use abrasive cleaning materials.

MAINTENANCE

The appliance should be serviced at least once a year by a 
Gas Safe Registered Engineer.

SCAN

for video

Summary of Contents for LOGIC SYSTEM 2 S15

Page 1: ...quire Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our website...

Page 2: ...ter direct on 0800 4085500 Ideal Heating is a member of the Benchmark scheme and fully supports the aims of the programme Benchmark has been introduced to improve the standards of installation and com...

Page 3: ...children 8 years and above Also persons with reduced physical sensory or mental capabilities or lack of experience and knowledge provided they have been given supervision or instruction concerning us...

Page 4: ...r parts of the system will be protected If a system frost thermostat has been installed the boiler must be set in winter mode there should not be a cross through the radiator symbol for the system fro...

Page 5: ...sit where access is not gained by the engineer Preventative solutions During cold weather set the central heating temperature knob A to maximum must return to original setting once cold spell is over...

Page 6: ...eer Contact a Gas Safe Registered Engineer NO 1 8 NORMAL OPERATION DISPLAY CODES The user control has one display to inform the user about the status of the boiler The display shows the status of the...

Page 7: ...supply is on at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of...

Page 8: ...eal Technical Helpline 01482 498663 Ideal Consumer Helpline 01482 498660 Ideal Parts 01482 498665 idealheating com Ideal Boilers Ltd pursues a policy of continuing improvement in the design and perfor...

Reviews: