5

User’s

 

YES

NO CENTRAL HEATING

Check the mains power is turned on 

and ensure mode control knob (B) is 

in the ON position

Does the boiler operate and provide 

central heating?

Check the time settings on the 

programmer are as you require and 

adjust if necessary

Check the programmer (external to 

the boiler) is in an “ON” position and 

the room thermostat is turned up

NO

See boiler “Operation Modes” and 

“Fault Codes” section.  If “

0 0

” is 

displayed then contact a Gas Safe 

Registered Engineer or in IE a 

Registered Gas Installer (RGII)

YES

NO HOT WATER

Check the mains power is turned on 

and ensure mode control knob (B) is in 

the ON position

Does the boiler operate and provide 

hot water?

Check the time settings on the 

programmer are as you require and 

adjust if necessary

Check the programmer (external to the 

boiler) is in an “ON” position and the hot 

water cylinder thermostat is turned up

NO

See boiler “Operation Modes” and 

“Fault Codes” section.  If “

0 0

” is 

displayed then contact a Gas Safe 

Registered Engineer or in IE a 

Registered Gas Installer (RGII)

6.  POINTS FOR THE BOILER USER

Note.

  

In line with our current warranty policy we would ask that you check through the following guide to identify any 

problems external to the boiler prior to requesting a service engineers visit.  Should the problem be found to be other 

than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is 

not gained by the engineer.

TROUBLESHOOTING

FOR ANY QUERIES PLEASE RING THE

IDEAL CONSUMER HELPLINE : 00353 (0)1 961 7700

NOTE. BOILER RESTART PROCEDURE - 

To restart boiler, press the “RESTART” button.

Summary of Contents for LOGIC SYSTEM S18IE

Page 1: ...e Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our website ide...

Page 2: ...erence should be made to the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler...

Page 3: ...our boiler efficiently using less gas turn the central heating temperature knob A to the position or lower In winter periods it may be necessary to turn the knob towards the MAX position to meet heati...

Page 4: ...l your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob A to maximum Must return to original setting once cold spell is over Place the h...

Page 5: ...grammer are as you require and adjust if necessary Check the programmer external to the boiler is in an ON position and the hot water cylinder thermostat is turned up NO See boiler Operation Modes and...

Page 6: ...central heating but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating hot water mode The boiler is operating in frost protection 7 NORMAL...

Page 7: ...s Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate Pipe for blockages refer to Section 3 2 Check other gas appliances in the...

Page 8: ......

Reviews: